When starting operating the generator, it's recommended to ground it. Before
starting the unit, remember that the total power of consumers connected should
not exceed the rated capacity of the generator.
Types of consumers and inrush current
Consumers (electrical devices connected to the generator) are divided into active
and reactive ones. Active ones are those, which energy is converted into heat
(heating devices).
Reactive are all consumers with electric motor. When you run the engine,
starting currents occur briefly, the size of which depends on engine design and
purpose. Please consider those starting currents when choosing a generator.
Most electric tools have starting current ratio 2-3. This means that when you
turn such tools required generator power have 2-3 times more power load. The
biggest factor of inrush current have such consumers as compressors, pumps,
washing machines.

BEFORE STARTING

Check the fuel level
1. Remove the fuel tank cap and check the fuel level.
2. Fill fuel to the level of the fuel filter and make sure there is no air in the fuel
system.
3. Screw the fuel tank cap back tightly.
Pic 2
Check the oil level (Pic 2)
1. Unscrew the oil level gage and clean
it with clean cloth.
2. Put the oil gage back without
FILL TO
screwing it.
3. Take the oil level gage out and check the
oil level according to the mark on a gage.
HERE
4. Add oil if it's level is below the mark
on a gage.
5. Screw the oil gage back.