OWNER'S MANUAL
Inverter Generator
KSB 10i
Please, read this manual
carefully before use!
EN

Advertisement

Table of Contents
loading

Summary of Contents for K&S BASIC KSB 10i

  • Page 1 OWNER’S MANUAL Please, read this manual carefully before use! Inverter Generator KSB 10i...
  • Page 2: Safety Information

    INTRODUCTION Thank you for your purchase of K&S BASIC products. This manual contains a brief description of safety, use and de- bugging. More information can be found on the official manufacturer’s website in the support section: ks-power.de/betriebsanleitungen. You can also go to the support section and download the full version of the manual by scanning the QR code, or on the website of the official importer of ТМ...
  • Page 3: Main Overview

    PRECAUTIONS WHEN WORKING WITH GASOLINE GENERATOR Do not start the generator operation upon presence of electric load! Disconnect the load before you stop the engine. Only mixture of gasoline and oil at a ratio of 50:1 (50 parts fuel to one part oil for two-stroke engines, the part of the oil in the mixture will be 2%) is recommended for the generator.
  • Page 4: Specifications

    SPECIFICATIONS Model KSВ 10i Voltage, V Maximum power, kW Nominal power, kW Frequency, Hz Current, A (max.) Outlets 1*16А Engine start manual Fuel tank volume, l Noise level Lpa (7m)/Lwa, dB 70/95 Engine model KSB 80i Engine volume, cm 42.7 Engine type gasoline powered one-cylinder, two-stroke Engine power, hp...
  • Page 5: Getting Started

    OPERATION INDICATOR OPERATION INDICATOR Once the generator is working in the normal mode, output voltage light is green. In case of overload, indicator lights red. After 2 minutes working in overload mode, protection device switches on and turns off the power generation to protect the connected electrical equipment and generator.
  • Page 6: Maintenance

    IN THE FIRST 20 OPERATING HOURS OF THE GENERATOR, THE FOLLOWING REQUIREMENTS SHOULD BE MET: IN THE FIRST 20 OPERATING HOURS OF THE GENERATOR, THE FOLLOWING REQUIREMENTS SHOULD BE MET: 1. During commissioning, do not connect power consumers, the power of which exceeds 50% of the nominal (operating) power of the device.
  • Page 7: Fuel Filter

    The manufacturer shall not be liable for any damage caused by IMPORTANT! failure to perform maintenance work. AIR FILTER TECHNICAL MAINTENANCE Air filter cleaning is to be performed each 50 hours of the generator operation (every 10 hours in unusually dusty conditions).
  • Page 8 STORAGE Storage room has to be dry and free from dust deposits. Storage room also has to be locked away from children and animals. It is recommended to store and use the generator at temperature of -20°С to +40°С. Avoid direct sunlight, rain on the generator.
  • Page 10 CONTACTS Deutschland: DIMAX International GmbH Flinger Broich 203 -FortunaPark- 40235 Düsseldorf, Deutschland www.ks-power.de Ihre Bestellungen Ihre Bestellungen orders@dimaxgroup.de Kundendienst, technische Kundendienst, technische Fragen und Unterstützung Fragen und Unterstützung support@dimaxgroup.de Garantie, Reparatur und Garantie, Reparatur und Service Service service@dimaxgroup.de Sonstiges Sonstiges info@dimaxgroup.de Polska: DIMAX International...