Sony HDS-X5800 Installation Manual page 44

Routing switcher processor
Hide thumbs Also See for HDS-X5800:
Table of Contents

Advertisement

1-11. Setting the On-Board Switches and Description of LEDs
8
8
8 Character display
8
8
ND601, ND602 :
The network IP address, S-BUS station ID and error
message are displayed.
The display is switched by the switch S103.
<Switches>
S101 : RESET
Resets the FP-129 board.
S102 : Rotary switch
This switch is factory use only. Do not change this setting.
S103 : MENU
The display of the character displays (ND601 and ND602)
is switched.
S104 : LED TEST
All of the LEDs (D1002 to D1004) on the FP-129 board
light on.
S105 : DISPLAY SELECT
The display modes of the D1 to D272 are switched.
S106 : DISPLAY ON/OFF
It triggers ON/OFF of the LEDs on the FP-129 board.
(Except for D1002 to D1004)
<Connectors>
CN101 :
Connector for factory use only.
CN102 :
Connector for writing into PLD (IC114)
<Variable resistor/TEST terminals>
RV102 : Variable resistor for temperature
adjustment
TP101 : Check terminal for temperature
adjustment
TP601 : + + + + + 5 V power voltage check terminal
<LEDs on LE-251 board>
D1 : DC + + + + + 12 V A
Power supply unit A system status indication
Lights in green when working normally. If the power
supply A system has an error, it lights in red. (Lights off
when both power supplies A1 and A2 are not inserted.)
1-36 (E)
D2 : DC + + + + + 12 V B
Power supply unit B system status indication
Lights in green when working normally. If the power
supply B system has an error, it lights in red. (Lights off
when both power supplies B1 and B2 are not inserted.)
D3 : CPU RUN A
Status indication of the CPU-339 board in slot A
Lights in green when working normally. If the CPU-339
board has a faulty operation, it lights in red. (Lights off
when the CPU-339 board is not inserted in the slot A.)
D4 : CPU RUN B
Status indication of the CPU-339 board in slot B
Lights in green when working normally. If the CPU-339
board has a faulty operation, it lights in red. (Lights off
when the CPU-339 board is not inserted in the slot B.)
D5 : FAN
Status indication of fan
Lights in green when all (14) fans are working normally. If
a fan is faulty, it lights in red.
D6 : TEMPERATURE
Status indication of temperature inside the machine
Lights in green during normal operation. Lights in red
when temperature inside the machine goes abnormally high.
D7 : BOARD
Status indication of option boards
Lights in green during normal operation. Lights in red
when abnormality occurs in any of the option boards.
D8 : REMOTE
Status indication of REMOTE1
Lights in green during normal operation. Lights in red
when the S-BUS link is faulty.
D9 : REF A
Status of indication of reference A system
Lights in green when the reference video signal is normally
input. Lights in red when there is abnormality.
(Lights off when the setting not to synchronize the signal
with the REFERENCE signal at the REF IN A connector,
is selected and at the same time when the reference video
signal is not inputted.)