Command Manual – System Maintaining and Debugging
H3C S3610&S5510 Series Ethernet Switches
undo clock timezone
View
User view
Parameters
zone-name: Time zone name, a string of 1 to 32 characters. It is case sensitive.
add: Positive offset to universal time coordinated (UTC) time.
minus: Negative offset to UTC time.
zone-offset: In the format of HH/MM/SS (hours/minutes/seconds), where HH is hours in
the range 0 to 23, MM is minutes in the range 0 to 59, and SS is seconds in the range 0
to 59. The zeros in the argument can be omitted except for indicating 0 hours.
Description
Use the clock timezone command to set the local time zone.
Use the undo clock timezone command to restore the local time zone to the default
UTC time zone.
By default, the local time zone is UTC zone.
After the configuration takes effect, use the display clock command to view the result.
The information such as log file and debug adopts the local time modified by time-zone
and daylight saving time.
Related commands: clock
summer-time repeating, display clock.
Examples
# Set the name of the local time zone to Z5, five hours ahead of UTC time.
<Sysname> clock timezone z5 add 5

1.1.5 command-privilege

Syntax
command-privilege level level view view command
undo command-privilege view view command
View
System view
Parameters
level level: Command level, in the range 0 to 3.
view view: Specifies a view.
Chapter 1 Basic Configuration Commands
datetime, clock
summer-time
1-5
one-off, clock