How To Replace The Ground Control Overlay - Genie S-45 XC Service And Repair Manual

Table of Contents

Advertisement

July 2019
9
Evenly tighten the nuts, beginning with the
lower center nut, working out and then up.
10 Install the new ribbon cables, connecting the
ground box overlay to the DISCON and
reinstall the DISCON door, using the Torx
head screws removed in step 4. Be sure to
fully lock the tabs after the ribbon calbes have
been fully inserted.
11 Reconnect the wire harness going to the
DISCON, then close and fasten the ground
box lid.
12 Reconnect the negative terminal to the start
battery and auxiliary batteries, if equipped.
Part No. 1286829GT
S-40 XC • S-45 XC • S-40 TraX • S-45 TraX
Repair Procedures
1-9
How to Replace the Ground Box
Control Overlay
1
Push in the red Emergency Stop button to the
off position at both the ground and platform
controls.
2
Disconnect the negative terminal from the
start battery and auxiliary battery, if equipped.
3
Open the ground box lid and remove the
switch contacts from the function enable and
E-Stop buttons and key switch. Do not
disconnect the wires. Insert a small
screwdriver into the loop at the base of the
contacts and engage the release mechanism.
Refer to Illustration 1.
Illustration 1
4
Unscrew the nut holding the buttons and key
switch and remove the key switch and buttons.
Note the orientation of the key switch so it can be
reassembled in the same position.
Service and Repair Manual
31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-40 traxS-40 xcS-45 trax

Table of Contents