Flashing four times – serial number has not been assigned. Bootloader is waiting
for a serial number to be assigned via RS-232 port. Cannot proceed to Bluetooth
initialization without a serial number assigned.
Flashing five times – unable to initialize Bluetooth module.
Serial Number: Used to identify each specific BLE Data Logger.
RS-232 Port: This port has two purposes:
o Can be used to connect the BLE Data Logger to a local or remote computer to
download the data that is stored in its internal flash memory or to collect the received
tag IDs transmitted in real-time.
o Can be configured to act as a communication port of the attached IS1001, RM310 or
FS1001A reader. This enables monitoring and configuring of the reader from either a
local or remote computer.
By default, the RS-232 port is set as the BLE Data Logger communication port.
Bluetooth Module: Enables Bluetooth wireless connection with the BLE Data Logger.
This connection has the same purposes and operates the same way as the RS-232 port.
Bluetooth Status LEDs: Indicate the status of the Bluetooth connection.
o Blue "LINK" LED:
Flashing slowly – ready to connect.
Steady on – connection established.
Flashing rapidly – data being transmitted or received.
o Yellow "BT_STATUS" LED:
Flashing once – ready to connect.
Flashing twice – connection established.
Steady on – configuration mode (CPU enters this mode for a short time after
restart).
IS1001 Status LEDs and Beeper: Indicate operational status of the attached IS1001
reader (not applicable when BLE Data Logger is attached to an RM310 or FS1001A
reader).