Using Communication Port to Monitor and Configure Attached Reader

Using Communication Port to Monitor and Configure
Attached Reader
The BLE Data Logger's RS-232 port and Bluetooth connections can be configured to act as the
attached reader's communication port.
1. Start the BioTerm communication program.
2. Make a connection to the BLE Data Logger using either RS-232 communication port or
Bluetooth.
3. Enter the CDC command to configure the connection as the reader communication port.
Note: There is no need to change communication speed to match the speed of the reader's
communication port.
4. Use any of the reader's commands to manage it (refer to the appropriate reader's User Manual
for the list of available commands and their description). Reader's firmware can be updated
through this communication port also (IS1001 only).
5. To close the communication port connection with the attached reader, press and hold the Ctrl
key and type QUIT.
This will reconfigure the RS-232 port and Bluetooth connections to communicate only with the
BLE Data Logger.
Important! Data IS NOT being written into BLE Data Logger's memory while the direct
communication channel to the reader is open. Remember to close this communication channel
after servicing the reader to prevent data loss. To prevent accidental data loss, the direct
communication channel will close automatically in 60 minutes if left open. Resetting the power to
BLE Data Logger will close the communication port connection with the attached reader.