Biomark IS1001 User Manual page 13

Ble data logger
Hide thumbs Also See for IS1001:
Table of Contents

Advertisement

DUM
{5|1|0|D}
Logger
LDF
{H|D}
LDS
{MM/DD/YYYY}
LPM
IS1001 BLE Data Logger User Manual
Set Detection Unique Mode {5} Last 5, {1} Last 1, {0} Off, {D}
Delay
Specifies how the tag ID is handled if it is received multiple
times from RM310 reader. Valid values are:
Last 5: The newly received tag ID is stored in the logger's
memory and is sent to the logger's communication ports (if
this feature is enabled) only if it is different from the last
five dissimilar tag IDs previously received from the RM310
reader.
Last 1: The newly received tag ID is stored in the logger's
memory and is sent to the logger's communication ports (if
this feature is enabled) only if it is different from the last
tag ID previously received from the RM310 reader.
Off: All tag IDs received from the RM310 reader are stored
in the logger's memory and are sent to the logger's
communication ports (if this feature is enabled). This is the
default value.
Delay: The newly received tag ID is stored in memory and
is sent to the communication ports (if this feature is
enabled) only if it is different from the last five dissimilar
tag IDs previously received from the RM310 reader or if the
specified number of seconds have passed since this tag ID
was first received. Use the DUD (Detection Unique
Delay) command to specify the delay value.
Note: The command is only applicable to tag IDs received
from RM310 reader and is only active when Attached Reader
Type is set to RM310.
Set Logger Tag ID Display Format {H} Hexadecimal, {D}
Decimal
Specifies the format for storing and displaying received tag
IDs. Valid values are Hexadecimal or Decimal. Default is
Hexadecimal.
Set Logger Date
Sets the logger's real-time clock present date. The date is
specified as mm/dd/yyyy.
Note: When data logger's Date/Time settings are updated
using "LDS"/"LTS" commands, Date/Time settings of the
attached IS1001 reader get updated automatically also.
Switch To RM310 Programming Mode
Switches the logger into RM310 programming mode.
Note: To exit RM310 programming mode power to the logger
must be reset. The logger will exit RM310 programming mode
automatically in 10 minutes.
Commands
10

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Biomark IS1001

Table of Contents