Commands - Biomark IS1001 User Manual

Ble data logger
Hide thumbs Also See for IS1001:
Table of Contents

Advertisement

Commands

Commands
The BLE Data Logger commands are made up of three or more characters followed by a carriage
return, as illustrated in the following example:
Generally, the first three letters designate the command group and the remaining letters/digits
designate the command parameters. The commands are not case sensitive. The backspace key
can be used to correct an improper command. The responses to the commands confirming the
requested action or setting parameter change are sent to both communication ports.
The following table is a list of the available Data Logger Board commands:
Cmd
Format
?
Communication
CDC
Ctrl+QUIT
CLR
{F|S}
CTL
{1|0}
Detection
DUD
{1-43200}
9
CTL1
Description
Print List of Commands
Used to display the list of available commands.
Open Direct Communication Channel to Reader
Used to open the direct communication channel to the
attached reader.
Close Direct Communication Channel to Reader
Used to close the direct communication channel to the
attached reader.
Set Local Communication Port Transfer Rate {F} Full, {S} Slow
Specifies the logger's communication ports transfer rate. Valid
options are Full or Slow. Default is Full.
Slow transfer rate option should be used whenever external
communication hardware has limited data transfer capabilities.
Set Tags Communication to Local Port {1} On, {0} Off
Specifies if received tag IDs are sent to the logger's
communication ports. Valid options are On or Off. Default is
Off.
Set Detection Unique Delay in Seconds
Specifies the delay value for the RM310 reader Detection
Unique Mode Delay option. Valid values are 1 – 43200
seconds. Default is 60 seconds.
Note: In order for Detection Unique Delay to take effect,
Detection Unique Mode must be set to Delay.
Note: The command is only applicable to tag IDs received
from RM310 reader and is only active when Attached Reader
Type is set to RM310.