1.
Turn off the power.
2.
Open the seal on the front panel by removing the sealing wire and screw the sealing
screw all the way in.
3.
Lift the handle to 90 degrees to release the latching mechanism.
The unit is pushed about 0.28 inches (7 mm) out of the case and the connectors are
separated.
4.
Pull the unit out of the case.
A070577 V4 EN
Figure 2:
Detaching a plug-in unit from the case
The protection relay features an automatic short-circuit mechanism in the
CT connector. Therefore, detaching the plug-in unit will not open the
secondary circuit of the CT which could cause dangerously high voltages.
Do not touch terminals inside the case after removing the plug-in unit.
Live terminals can be inside the case.