Omron S8VK-G Series Manual page 36

Hide thumbs Also See for S8VK-G Series:
Table of Contents

Advertisement

Power ratings
Item
With 100-VAC input 84% typical
Efficiency
With 200-VAC input 83% typical
Voltage *1
Frequency *1
With 100-VAC input 1.7 A max., 1.3 A typical
Current
With 200-VAC input 1.0 A max., 0.68 A typical
Power factor
Input
Harmonic current regulation
With 100-VAC input 0.5 mA max.
Leakage current
With 200-VAC input 1.0 mA max.
With 100-VAC input 17.5 A max., 14 A typical
Inrush current *2
With 200-VAC input 35 A max., 28 A typical
Voltage adjustment range *3
Ripple noise voltage (at rated I/O)
Input variation influence
Load variation influence (rated input voltage)
Output
Temperature variation influence
With 100-VAC input
Startup time
(at rated I/O) *2
With 200-VAC input
With 100-VAC input
Output hold time
(at rated I/O) *2
With 200-VAC input
Overload protection *2
Overvoltage protection *2, *4
Output voltage indication *5
Output current indication *5
Peak-hold current indication *5
Maintenance forecast monitor indication *5
Additional
Maintenance forecast monitor output
functions
Total run time monitor indication *5
Total run time monitor output *5
Undervoltage alarm indication *5
Undervoltage alarm output terminals
Parallel operation
Series operation
Operating ambient temperature
Storage temperature
Operating ambient humidity
Dielectric strength
Insulation resistance
Vibration resistance
Shock resistance
Output indicator
Conducted
Emissions
Other
EMI
Radiated
Emissions
EMS
Approved standards *11
SEMI *11
Weight
*1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in
ignition or burning.
*2. For a cold start at 25°C. Refer to Engineering Data on page 18 for details.
*3. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +15% of the voltage adjustment range (by more than +10% for 240-W models with indication monitor).
When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged.
*4. To reset the protection, turn OFF the input power for three minutes or longer and then turn it back ON.
*5. Displayed on 7-segment LED. (character height: 8 mm)
*6. Resolution of output voltage indication: 0.1 V, Precision of output voltage indication: ±2% (percentage of output voltage value, ±1 digit)
*7. Resolution of output current indication: 0.1 A; Precision of output current indication: ±5% F.S. ±1 digit max. (specified by rated output voltage)
*8. Resolution of peak-hold current indication: 0.1 A; Precision of peak-hold current indication: ±5% F.S. ±1 digit max. (specified by rated output voltage);
Signal width required for peak-hold current: 20 ms
*9. A Type and B Type: Sinking, AP Type and BP Type: Sourcing, BE Type: No alarm output.
*10. S8VS-06024A, S8VS-09024A/AP, S8VS-12024A/AP, S8VS-18024A/AP, and S8VS-24024A/AP only
*11. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
60 W
Maintenance
Type
Standard
forecast monitor
83% typical
85% typical
100 to 240 VAC (allowable range: 85 to 264 VAC or 80 to 370 VDC *11)
50/60 Hz (47 to 450 Hz)
1.7 A max., 1.3 A typical
1.0 A max., 0.78 A typical
---
Conforms to EN61000-3-2
−10% to 15% (with V. ADJ) (The voltage cannot be adjusted for the S8VS-09024@@@S-@.)
70 mV max.
90 mV max.
0.5% max. (at 85- to 264-VAC input, 100% load)
1.5% max. (with rated input, 0 to 100% load)
0.05%/°C max.
620 ms typical
460 ms typical
400 ms typical
290 ms typical
34 ms typical
33 ms typical
158 ms typical
154 ms typical
105% to 160% of rated load current (101% to 110% of rated load current for the S8VS-09024@@@S-@), inverted L voltage drop, intermittent, automatic reset
Yes
Yes (selectable) *6
No
Yes (selectable) *7
No
Yes (selectable) *8
No
No
Yes (selectable)
No
No
No
No
Yes (selectable)
No
No
Yes for up to 2 Power Supplies (with external diode)
Refer to the derating curve in . (with no icing or condensation)
−25 to 65°C
25% to 85% (Storage humidity: 25% to 90%)
3.0 kVAC for 1 min. (between all inputs and outputs/ alarm outputs; detection current: 20 mA)
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA)
1.0 kVAC for 1 min. (between all outputs/ alarm outputs and PE terminals; detection current for standard models: 30 mA, detection
current for models with indication monitor: 20 mA)
500 VAC for 1 min. (between all outputs and alarm outputs; detection current: 20 mA)
100 MΩ min. (between all outputs/ alarm outputs and all inputs/ PE terminals) at 500 VDC
10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
10 to 150 Hz, 0.35-mm single amplitude (5 G max.) for 80 min each in X, Y, and Z directions
2
150 m/s
, 3 times each in ±X, ±Y, and ±Z directions
Yes (color: green)
Models with indication monitor: Conforms to EN61204-3 EN55011 Class A and based on FCC Class A, Conforms to EN61204-3
EN55011 Class B *11
Standard models: Conforms to EN61204-3 EN55011 Group 1 Class B and based on FCC Class A
Models with indication monitor: Conforms to EN61204-3 EN55011 Class A, Conforms to EN61204-3 EN55011 Class B *11
Standard models: Conforms to EN61204-3 EN55011 Group 1 Class B
Conforms to EN61204-3 high severity levels
UL: UL 508 (Listing; Class 2 Output: Per UL1310), UL UR: UL
60950-1 (Recognition),
cUL: CSA C22.2 No.107.1 (Class 2 Output: Per CSA C22.2 No.
223),
cUR: CSA C22.2 No.60950-1,
EN/VDE: EN 50178 (= VDE 0160), EN 60950-1
(= VDE 0805 Teil 1)
KOSHA S Mark *10
F47-0706 (With 200-VAC input)
330 g max.
Total run time
Standard
monitor
forecast monitor
83% typical
83% typical
84% typical
85% typical
2.3 A max., 1.9 A typical
2.3 A max., 1.9 A typical
1.4 A max., 1.0 A typical
1.4 A max., 1.2 A typical
250 mV max.
150 mV max.
460 ms typical
660 ms typical
300 ms typical
420 ms typical
28 ms typical
28 ms typical
132 ms typical
136 ms typical
Yes (selectable) *6
No
Yes (selectable) *7
No
Yes (selectable) *8
No
No
No
Yes (selectable)
Yes (transistor output),
30 VDC max., 50 mA max. *9
Yes (selectable)
No
No
Yes (selectable)
Yes (transistor output), 30 VDC max., 50 mA max. *9
UL: UL 508 (Listing)
UL Listed (S8VS-09024@@@S-@ only.): UL 508 (Listing, Class 2
Output: Per UL1310),
UL UR: UL 60950-1 (Recognition),
cUL: CSA C22.2 No.107.1,
cUL (S8VS-09024-@@@S-@ only): CSA C22.2 No.107.1 (Class 2
Output: Per CSA C22.2 No. 223),
cUR: CSA C22.2 No.60950-1,
EN/VDE: EN 50178 (= VDE 0160),
EN 60950-1 (= VDE 0805 Teil 1)
KOSHA S Mark *10
490 g max.
S8VS
90 W
Maintenance
Total run time
monitor
No
No
Yes (selectable)
Yes (transistor output),
30 VDC max., 50 mA max. *9
5