2.

ADJUSTMENTS

Adjust the MU-190 according to the equipment connected.
Note: Sections 2.2, 2.3 and 2.4 are for Non-SOLAS.
2.1

Installation Settings

The [INSTALLATION SETTING] menu appears only when the power is turned on for the first time
after installation.
INSTALLATION SETTING
EXT BRILL CTRL
SERIAL BAUDRATE
COLOR CALIBRATION
KEY LOCK
SAVE AND EXIT
For FMD-3200, FCR-21x9, FAR-32x0, no adjustment is necessary. Keep this equipment in the de-
fault settings.
For IMO radar (FAR-21x7), ECDIS (FEA-2107), chart radar (FCR-21x7) or Non-SOLAS, adjust
this equipment according to the equipment connected, referring to the following table.
Connected
Connected
equipment
FMD-3200,
EC-3000
FCR-21x9
FAR-32x0
FEA-2107,
EC-1000C
FCR-21x7
FAR-21x7
RPU-013
Other
Bold italic items: Default setting
*1:
To connect to the processor unit of a radar, connect the video signal cable to the DVI-D1 port.
Then, select DVI1 to display the radar picture (see section 3.4).
*2:
"DVI PWR SYNC" is the slide switch at the bottom rear of the monitor unit. See the "Slide
switch" below.
Slide switch
Set the slide switch (located between RGB and DVI ports) to OFF when you connect the RGB
signal or both RGB and DVI signals. Otherwise, the monitor will not turn on. The slide switch is set
at the factory to ON to control the power on/off from the equipment connected via DVI signal.
RGB port
              Bottom rear of the monitor unit
RS-485
(OFF/DVI1/DVI2/RS-232C/RS-485/USB)
4800bps
(4800/9600/19200/38400)
ON
(OFF/ON)
ON
(OFF/ON)
YES
(NO/YES)
EXT BRILL
Unit
CTRL
RS-485
RS-232C
1
DVI *
-
OFF
Slide switch
SERIAL
COLOR
BAUDRATE
CALIBRATION
4800
9600
-
OFF
-
OFF
ON (Default setting)
Slide switch ON (Default setting)
OFF
12
Menu
Menu item
KEY
LOCK
ON
ON
ON
ON
ON
OFF
DVI port
DVI PWR
2
SYNC *
ON
ON
ON
OFF

Hide quick links: