ProControl Integration Specifics
Control Network ID
Select the Modbus address of the ProControl 1KS. The
range is from 1 though 247.
Modbus communications for reading back information is
available even when Discrete I/O control is enabled.
Status Verification of Automatic
Operation
Several screens allow viewing of control interface status
information.
Discrete I/O bits as used on the ProControl 1KS are
available in Advanced Setup Screen 8 and Advanced
Setup Screen 9 If control is through the Network inter-
face the status data comes from those registers.
This data is updated live.
F
. 63. Advanced Setup Screen 8
IG
F
. 64. Advanced Setup Screen 9
IG
50
Discrete I/O vs Network
Communications
The ProControl 1KS Automatic system does not use a
Booth Control. Instead, it uses Discrete I/O or Network
Communications to drive the system. Each method can
be used exclusively, or both at the same time.
In Automatic mode, the following fields can be set to
"Discrete" or "Network" (see Configure Screen 6 on
page 31):
Flow Control
Proportioning
Gun 1 Trigger
NOTE: In Semi-automatic mode, only the Proportioning
field is available.
NOTE: The Manual Override function enables you to
operate the system before the automation (PLC) is avail-
able. Manual Override still requires some communica-
tion through Discrete I/O or Network Communications.
Although Manual Override is not intended to be the main
mode of control, it can be used if proper Gun Trigger
Input is provided.