INNO Instrument View 8+ User Manual page 42

Arc fusion splicer
Table of Contents

Advertisement

Error Message
There's dust or dirt
on the fiber surface
Dust or dirt is on the
lens or LEDs
"Cleaning Arc
Fiber is Dirty
time" is too short
Splice the fibers
whose cores are
difficult to find by
the way of core
alignment.
Too much [Overlap]
Fat Splicing Point
Pre-fuse power or
Thin Splicing Point
time is set too high
"Overlap" setting
Cause
Prepare the fiber (stripping,
cleaning, and cleaving) again.
Execute the "Dust Check". If dust
or dirt exists, clean the lenses or LEDs
Set the "Cleaning Arc time" to
180ms
Splice the fibers whose cores are
difficult to find by MM splice mode
(cladding layer alignment).
Adjust or initialize "Overlap" setting.
setting
The motor is not
Calibrate the arc power with the "Arc
calibrated.
Calibration" function.
Inadequate arc
Calibrate the arc power with the "Arc
power
Calibration" function.
Adjust or initialize "Pre-fuse Power"
or "Pre-fuse Time" settings.
Insufficient
Adjust or initialize
"Overlap" setting
User's Manual
INNO Instrument, Inc.
Solution