European Compliance; Energy Consumption - Arris TG 3442 User Manual

Touchstone tg3442s telephony gateway
Hide thumbs Also See for TG 3442:
Table of Contents

Advertisement

The shield of the coaxial cable must be connected to earth (grounded) at the entrance to
the building in accordance with applicable national electrical installation codes. In the
European Union and in certain other countries, CATV installation equipotential bonding
requirements are specified in IEC 60728-11, Cable networks for television signals, sound
signals and interactive services, Part 11: Safety. This equipment is intended to be
installed in accordance with the requirements of IEC 60728-11 for safe operation.
If the equipment is to be installed in an area serviced by an IT power line network, as is
found in many areas of Norway, special attention should be given that the installation is
in accordance with IEC 60728-11, in particular Annex B and Figure B.4.
In areas of high surge events or poor grounding situations and areas prone to lightning
strikes, additional surge protection may be required (i.e. PF11VNT3 from American
Power Conversion) on the AC, RF, Ethernet and Phone lines.
When the Telephony Gateway is connected to a local computer through Ethernet cables,
the computer must be properly grounded to the building/residence AC ground network.
All plug-in cards within the computer must be properly installed and grounded to the
computer frame per the manufacturer's specifications.
Ensure proper ventilation. Position the Telephony Gateway so that air flows freely
around it and the ventilation holes on the unit are not blocked.
Do not mount the Telephony Gateway on surfaces that are sensitive to heat and/or
which may be damaged by the heat generated by the modem, its power supply, or other
accessories.

European compliance

The full text of the EU declaration of conformity is available at the following internet
address: http://www.arris.com/consumers/eudoc.

Energy Consumption

In accordance with Ecodesign Directive 2009/125/EC, this device is equipped with a power
switch. The following energy consumption figures apply (measured with a wattmeter at the
outlet):
Final 1.0 October 2018
© 2018 ARRIS Enterprises LLC. All Rights Reserved.
As indicated by this symbol, disposal of this product or battery is
governed by Directive 2012/19/EU of the European Parliament and of the
Council on waste electrical and electronic equipment (WEEE). WEEE
could potentially prove harmful to the environment; as such, upon
disposal of the Telephony Gateway the Directive requires that this
product must not be disposed as unsorted municipal waste, but rather
collected separately and disposed of in accordance with local WEEE
ordinances.