  • Page 1 Stanza wiring and programming guide...
  • Page 2 Stanza Wiring and Programming Guide Stanza Drives are available for control of Draperies and Roller Shades. Stanza Shades and Drapes can be controlled as part of a Stanza Integrated System, incorporating Stanza lighting controls, or as a Stanza Standalone System, without lighting controls. This Stanza Wiring and Programming Guide describes how to set up Stanza shades and drapes in both applications.
  • Page 3: Table Of Contents

    Table of Contents Page Basic Operation Keypad Functions IR Remote Functions Wiring Infrared Receiver Stanza Standalone System Stanza Integrated System 9-10 Contact Closure Contact Closure Specification Setting Limits From the Drive From an Infrared Remote 13-16 Programming Assigning Drive to Remote Control...
  • Page 4: Keypad Functions

    A maximum of 4 Shades or Drapes can be wired to any keypad output: • daisy chained or homerun Stanza Standalone System Keypads provide contact closures to the Shade or Drape, • and require no input power. Single Group Keypad...
  • Page 5: Ir Remote Functions

    Tapping any button while Shade or Drape is moving will cause it to stop • All Shades or Drapes with an IR receiver will respond to the Single Group IR Remote as shipped, • without any additional programming Page 4 Stanza Wiring and Programming Guide...
  • Page 6: Wiring

    Close Bottom Group Same Functions as above All Stanza Drives with an IR receiver will respond to the Top Group of buttons without any • programming Shade or Drape Group Assignment is required to allow the Bottom Group of buttons to •...
  • Page 7: Infrared Receiver

    Infrared Receivers Remote IR Eye Lutron offers a remote infrared eye for Stanza. It is a small dome connected to the Drive by a ® 22 in (560 mm) cable. The remote infrared eye plugs into a dedicated IR connector on the Drive. Ten foot extensions are available if the layout requires the IR eye to be located further from the Drive.
  • Page 8: Stanza Standalone System

    Single Drive Wiring Wire Type A IR Receiver 24 V Close Open Terminal block of Drive controlling single Shade or Drape Stanza Drapery or Single Group Roller Shade Drive Keypad Wire Type B Single group IR Transmitter SZ-PS-1-50 Power Supply Notes: Standalone shade or drapery drives can be controlled with a keypad, IR remote, or both.
  • Page 9: Contact Closure

    24 V 24 V Close Receiver Close Open Open Terminal block of Drive controlled by Wire Type A Stanza Drapery or Group 1 buttons Roller Shade Drive Dual Group Keypad 24 V 24 V Close Close Open Optional IR Open...
  • Page 10: Stanza Integrated System

    Contact Closure Interface 24 V Close Open Wire Type A Terminal block of Drive controlling Stanza Drapery or single Shade or Roller Shade Drive Drape Wire Type B SZ-PS-1-50 Power Supply Notes: SZ-IO outputs programmed as a 0.25 second momentary contact closure output •...
  • Page 11: Contact Closure

    SZ-PS-1-50 Power Supply SZ-IO Wire Type B 24 V Close Open Terminal block of Drive controlling Wire Type A Stanza Drapery or sheer Shade or Roller Shade Drive Drape 24 V Close Open Terminal block of Drive controlling blackout Shade...
  • Page 12: Contact Closure Specification

    Wire Type B SZ-PS-1-50 Power Supply Notes: The Stanza Drive accepts Class 2, dry contact closure inputs. The contact closure device • must be capable of switching 12 V at 4 mA. Momentary dry contact closure inputs require a minimum closure time of 0.25 seconds.
  • Page 13: From The Drive

    Green LED will turn on. Move the Shade or Drape to desired Close Limit by pressing arrow buttons. Press and hold the Close Limit button until the Green LED flashes. Close Limit is stored. Page 12 Stanza Wiring and Programming Guide...
  • Page 14: From An Infrared Remote

    • bottom Group prior to limit setting. Refer to Section 11 By default the Single Group IR Remote is assigned to all Stanza Drives and cannot • be reassigned to specific drives. Limits can be set at the Drive, or from the IR Remote.
  • Page 15: Setting Limits

    Move Shade or Drape to desired Close Close Limit by pressing the Raise or Lower buttons. 10.8 Press and Hold the Close Limit Open Close button until the Green LED on the Drive flashes. Close Limit is stored. Page 14 Stanza Wiring and Programming Guide...
  • Page 16 Open Limit by pressing the Raise or Lower buttons. Open Close 10.12 Press and Hold the Open Limit button until the Green LED Open on the Drive flashes. Open Limit Close is stored. Open Close Page 15 Stanza Wiring and Programming Guide...
  • Page 17 Close Limit by pressing the Raise or Lower buttons. Open Close 10.16 Press and Hold the Close Limit button until the Green LED Open on the Drive flashes. Close Limit Close is stored. Open Close Page 16 Stanza Wiring and Programming Guide...
  • Page 18: Programming

    Each Shade or Drape in the system requires its own Infrared Receiver (SV-IR) • to allow it to be controlled via IR. By default the single Group IR Remote is assigned to all Stanza Drives and cannot • be reassigned to specific drives.
  • Page 19: Storing Favorite Preset

    Note: If the LED on the Drive flashes orange in step 12.2, Programming lockout is enabled and favorite preset is not stored. Refer to Section 13 to disable and repeat steps 12.1 and 12.2. Page 18 Stanza Wiring and Programming Guide...
  • Page 20: Storing Favorite Preset

    Note: If the LED on the Drive flashes orange in step 12.4, Programming lockout is enabled and favorite preset is not stored. Refer to Section 13 to disable and repeat steps 13.3 and 13.4. Page 19 Stanza Wiring and Programming Guide...
  • Page 21: Programming Lock Out

    Favorite Preset button for 5 seconds. Open Close LED on the Drive will turn on steady Green then go out to indicate programming is unlocked. This will unlock all Drives assigned to the Top and Bottom Groups. Page 20 Stanza Wiring and Programming Guide...
  • Page 22: Restoring Default Settings

    LED flashes Green then turns on steady. 14.3 Press and hold CW arrow button until LED flashes Green then turns on steady. 14.4 Press and hold CCW arrow button until LED flashes Green then turns on steady. Page 21 Stanza Wiring and Programming Guide...
  • Page 23: Sz-Io Diagnostics Mode

    Note: Diagnostic mode will exit automatically after 5 minutes of inactivity. Pressing the addressing button will reset the inactivity time and the unit will remain in diagnostic mode. SZ-IO Rear View Contact Closure Outputs (CCO) Contact Closure Inputs (CCI) Page 22 Stanza Wiring and Programming Guide...
  • Page 24: Troubleshooting

    Not all Drives have their own IR Receiver Verify the voltage on the input terminal of the Drives not responding to Contact Stanza Drive. Voltage should be 9-10 V--- Closures from keypad, SZ-IO or third party between open/close and com when contact contact closure closure is not actuated.
  • Page 25: Limited Warranty

    If any manufacturing defect exists OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATIONS OR in any of the components of a System other than the External Stanza Components, so long as Customer EXCLUSIONS MAY NOT APPLY TO YOU.

Table of Contents