G3PJ
2. Removing Wires from the Terminal
Use the following procedure to remove wires from the terminal.
The same method is used to remove stranded wires, solid wires, and
ferrules.
1. Hold a flat-blade screwdriver at an angle and insert it into the
release hole.
Flat-blade screwdriver
1
2. With the flat-blade screwdriver still inserted into the release hole,
remove the wire from the terminal insertion hole.
3. Remove the flat-blade screwdriver from the release hole.
3. Recommended Ferrules and Crimp Tools
Recommended ferrules
Applicable
Ferrule
wire
Conduct
length
Phoenix Contact
(mm
2
) (AWG)
(mm)
0.25
24
8 AI0.25-8
0.34
22
8 AI0.34-8
0.5
20
8 AI0.5-8
0.75
18
8 AI0.75-8
1
18
8 AI1-8
1.5
16
8 AI1.5-8
Recommended crimp tool
CRIMPFOX6
Note: 1. Make sure that the outer diameter of the wire is smaller than
the inner diameter of the insulating sleeve of the
recommended ferrule.
2. Make sure that the ferrule processing dimensions conform
to the following figure.
8 mm
2.1 mm max.
2.7 mm max.
8
10 to 15˚
2
Wire
3
Recommended ferrules
Weidmuller
Wago product
product
product
H0.25/12
FE-0.25-8N-YE
H0.34/12
FE-0.34-8N-TQ
H0.5/14
FE-0.5-8N-WH
H0.75/14
FE-0.75-8N-GY
H1.0/14
FE-1.0-8N-RD
H1.5/14
FE-1.5-8N-BK
PZ6 roto
Variocrimp4
Recommended Flat-blade Screwdriver
Use a flat-blade screwdriver to connect and remove wires.
Use the following flat-blade screwdriver.
The following table shows manufacturers and models as of 2015/Dec.
Side
Front
2.5 mm dia.
0.4 mm
2.5 mm
Model
XW4Z-00B
Omron
ESD 0.40✕2.5
Wera
SZF 0.4✕2.5
Phoenix Contact
0.4✕2.5✕75 302
Wiha
AEF.2.5✕75
Facom
*1
210-719
Wago
SDI 0.4✕2.5✕75
Weidmuller
*1
98 20 25
KNIPEX
*1.
Insulated types of Flat-blade Screw driver, strongly recommended
to prevent from an electric shock.
Fuses
• Use a quick-burning fuse on the output terminals to prevent
accidents due to short-circuiting. Use a fuse with equal or greater
performance than those given in the following table.
Recommended Fuse Capacity
Rated G3PJ output
Applicable SSR
current
15 A
G3PJ-@15B Series
25 A
G3PJ-@25B Series
EMC Ditective Compliance
EMC direcives can be complied with under the following conditions.
1. The G3PJ with Rated Load Voltage of 24 to 240 VAC (2@@B
model)
• A capacitor must be connected to the load power supply.
• The input cable must be less than 3 m.
INPUT
G3PJ
Recommended Capacitor (Film capacitor) : 1µF , 250VAC
3 m Max.
2. The G3PJ with Rated Load Voltage of 100 to 480 VAC (5@@B
model)
• A capacitor must be connected to the input power supply.
• A capacitor, varistor and toroidal core must be connected to the
load power supply.
• The input cable must be less than 3 m.
INPUT
G3PJ
3 m Max.
Recommended Capacitor (Film capacitor) : 0.05µF , 500VAC (LOAD)
Recommended Varistor : 470V, 1750A
Recommended Troidal core : NEC/TOKIN:ESD-R-25B or equivalent
Manufacturer
*1
Fuse
(IEC 60269-4)
32 A
LOAD
OUTPUT
Troidal core
LOAD
OUTPUT
0.1µF , 250VAC (INPUT)