3.4.2 General specifications

Item
Control mode
Output Frequency
Starting Torque
Frequency resolution
Frequency
Frequency setting
Frequency limit
Run
Operation set
V / F curve setting
Carrier frequency
Acceleration and
deceleration control
Multifunction input
Main
Multifunction output
Control
Multifunction analog output
Features
Main features
LED display
Display
LED status indicator
Overload protection (OL1)
Overload protection (OL2)
Over voltage
Under Voltage
Protective
Momentary Power Loss
Functions
Restart
Stall Prevention
Short-circuit output terminal
Grounding Fault
Other protection features
V/F, SLV, PMSLV control mode
0.01~599.00Hz
150% / 1Hz (SLV mode),150% / 3Hz(V/F mode)
Digital input:0.01Hz
Analog input:0.06Hz/60Hz
Keypad:set directly with ▲▼keys or the VR on the keypad
External input terminals: AI1、AI2 (0/2-10V, 0/4-20mA)
Multifunction input UP/DOWN function(Group 3)
Set frequency by communication method
Lower and upper frequency limits 3 skip frequency settings.
Keypad RUN/STOP buttom
External terminals:
Multi-operation mode 2/3 wires selection
JOG operation
Run signal by communication method
15 fixed curves and 1 customized curve
1~16kHz (factory setting is 5kHz)
2 off acceleration/deceleration time parameters
4 off S curves parameters
Refer to description on Group 3
Refer to description on Group 3
Refer to description on Group 4
Overload detection, 16 preset speed, Auto-run, Acc/Dec
switch(2 stages), Main/Alt run command select, Main/Alt
frequency command select, PID control, Torque boost, V/F
start frequency, Fault reset, Fire mode,
Parameter, Paramete value, Frequency, Line speed, DC
voltage, Output voltage, Output current, PID feedback, Input
and output terminal status, Heat sink temperature, Firmware
version, Fault list.
Run, Stop, Forward, Reverse and etc.
Electrical overload protection curve
H.D mode:150% for 60s
N.D mode:120% for 60s
200V Class:DC bus voltage higher than 410Vdc
400V Class:DC bus voltage higher than 820Vdc
200V Class:DC bus voltage lower than 190V
400V Class:DC bus voltage lower than 380V
Inverter auto-restart after a momentary power loss
Stall prevention for acceleration/deceleration operation
Electronic circuit protection
Electronic circuit protection
Protection for overheating of heat sink, Fault output, Reverse
prohibit, Prohibit for direct start after power up and error
recovery, Parameter lock up, STO (Safety Torque Off).
3-31
E510s
Multi-Pump function.
(200% for 2s)