5.2 Troubleshooting

Faults
Charging LED indicator is off during
daytime and the monitor shows
Disconnect.
Monitor interface PV shows Measure
Err, MOS-I Short, MOS-C Short, MOS
Break.
Fault indicator flashing
Monitor interface BATT shows LVD.
Charging and discharging circuit is off
and monitor interface BATT shows OVD.
Fault indicator flashing
Charging and discharging circuit is off
and the BATT of monitoring interface
shows Over Temp.
Fault indicator flashing
Monitor interface BATT shows Rated V
Err.
Charging indicator and Fault indicator
flashing
Discharging circuit is off and monitor
shows Over Load.
Fault indicator flashing
Discharging circuit is off and the LOAD
monitor shows Short.
Fault indicator flashing
Charging and discharging circuit is off
Possible reasons
PV Array Disconnection
MOS-I Or MOS-C Damage
Battery Over Discharged
Battery Over Voltage
Operating Ambient
Temperature
(local temperature sensor) Or
Battery Temperature
(remote temperature sensor)
Over Temperature
System Voltage Error
Load Overload▽
Load circuit is short
Electronical Component
21
Troubleshooting
Check that PV and battery wire connections are correct and
tight.
Please restart controller;
if the fault still exists, switch off controller immediately and
contact the supplier to make maintenance.
The controller cut off the output automatically and recover when
fully charged.
switch off the wiring of solar array and measure the voltage of
battery whether is too high.
When operating ambient temperature or battery temperature
reaches exceeds 65º C controller will cut off input and output
circuit automatically.
When
the
temperature
automatically reconnect input and output circuit.
Check whether the battery voltage is consistent with the system
voltage set by the controller.
①Please reduce the number of electric equipments.
②Restart the controller.
①Check
carefully
loads
②Restart the controller.
Please restart controller, if the fault still exists, cut off charging
is
below
55℃,
controller
connection,
clear
the
will
fault.