Download Print this page

Crestron BiAmp AudiaFlex Quick Start Manual page 3

Advertisement

Partner: BiAmp
Model: AudiaFlex & Nexia
Device Type: DSP
FEEDBACK:
Volume_Gauge
Volume_Level_Sign_Unscaled
Volume_Level_Text
errorReceived
To_Processor
PARAMETERS:
Volume_Device_Type
Volume_Device_ID
Volume_Device_Instance
Volume_Index_1
Volume_Index_2
Volume_Upper_Limit
Volume_Lower_Limit
Volume_Step
TESTING:
OPS USED FOR TESTING:
SIMPL WINDOWS USED FOR TESTING:
DEVICE DB USED FOR TESTING:
Analog value indicating the current volume level. To be displayed using a gauge on a
A
touch panel.
Analog volume level value. This is the signed dB level. To be displayed using a digital
A
gauge on a touch panel.
S
Serial signal indicating the current volume level. This will show from -100.0 to 12.0
Digital output that will be set high when the BiAmp sends an error to the module. If this
output is set high it is an indication of one of a couple of things. The instanceID, device
D
type, or indexes entered in the parameter fields are incorrect. The other possible cause
is that the wrong or no configuration file has been loaded into the BiAmp. Once this
output is set high, you will still be able to poll for status but no controls will function.
Serial data signal to be connected to the From_Modules on the BiAmp AudiaFlex +
S
Nexia Command Processor Serial v7.5.1 module or the BiAmp AudiaFlex + Nexia
Command Processor IP v7.5.1 module.
ASCII
Select the proper device type from the drop down list.
ASCII
Device address automatically assigned after the BiAmp .dap file is compiled
ASCII
Logic Block ID assigned after the BiAmp .dap file is compiled
Volume index to be controlled. This is the input, channel or output number being
ASCII
controlled.
This used for cross point type devices. Typically, this would be zero. For cross points
ASCII
this is the output number for the cross point being controlled.
ASCII
This is the upper limit for the volume level being controlled. This is the signed dB value.
ASCII
This is the lower limit for the volume level being controlled. This is the signed dB value.
ASCII
Select the volume step value from the dropdown list. Default is 1.0 dB.
PRO3: 1.501.0013
4.03.20
73.00.001.00

Advertisement

loading

This manual is also suitable for:

Nexia level control