Sub-menu
1.7.10 Fan control
1.7.11 Temp events
1.7.11.1 Temp 1 min
1.7.11.2 Temp 1 max
1.7.11.3 Temp 2 min
1.7.11.4 Temp 2 max
1.7.11.5 Temp 3 min
1.7.11.6 Temp 3 max
1.7.11.7 Fresh temp. timeout
1.7.12 Optical sensor
1.7.12.1 Max failure
1.7.12.1.1
Max failure option
1.7.12.2 Max sel. failure
1.7.12.2.1
Max failure option
1.7.12.3
Additional turn max
1.7.12.4
Additional turn step
Version 3.4 / November 2016
FOODBOX / FOODBOX LONG
Description
Select the operational mode of the refrigeration unit's fan:
• Always ON – working always
• Only when cooling – works only when in cooling mode
• Cooling and defrosting – works when cooling and de-freez-
ing
Set range of monitored values for temperature sensors
Set minimum temperature for sensor 1, upon reaching which
the event is logged
Set maximum temperature for sensor 1, upon reaching which
the event is logged
Set minimum temperature for sensor 2, upon reaching which
the event is logged
Set maximum temperature for sensor 2, upon reaching which
the event is logged
Set minimum temperature for sensor 3, upon reaching which
the event is logged.
Set maximum temperature for sensor 3, upon reaching which
the event is logged.
Maximal temperature sensor 1 out of range duration (in min-
utes)
Configures optical sensors, used to record the dispensing of
products
Set the number of failures in attempting to dispense the prod-
uct from all cells in the Machine, upon reaching this number the
Machine reacts as per the settings in s.c.1.7.12.1.1
The Machine's reaction to failures set in s.c.1.7.12.1:
• Machine block – restrict sales from all the cells;
• Disable refund – No refund of deposited credit
Set the maximum number of failures to dispense product from
a single cell.
Upon reaching this number the Machine reacts, as per the set-
tings of 1.7.12.2.1
Machine's actions upon reaching the maximum number of
failed attempts at dispensing the product set in s.c.1.7.12.2:
• Machine block – stop sales from the given cell;
• Disable refund – no refund of credit deposited
Maximum additional turn of spiral in case of failure (to dispense
product)
The step of additional turn of spiral monitored by the optical
sensors
Value
Always on
Only cooling
Cooling & defrosting
Enter
temperature
-10...+60
Enter
temperature
-10...+60
Enter
temperature
-10...+60
Enter
temperature
-10...+60
Enter
temperature
-10...+60
Enter
temperature
-10...+60
Enter number
0...65000
No
Yes - to sub-menu
Enter number
0...255
0-turns OFF
the option
Machine block
Disable refund
Enter number
from 0...255
0=Disable option
Machine block
Disable refund
1/2
3/8
1/4
1/8
1/2
1/4
1/8
Page 55