CAUTION! Avoid static discharges
The RF input and output connections are static-sensitive and should not be subjected
to static discharge.
CAUTION! Use the correct line supply source
It is essential that the amplifier operates from a line supply source that does not apply
voltages and frequencies between the line supply conductors (or between either line
supply conductor and ground) that are outside the range detailed in the specification
sheet.
CAUTION! Do not obstruct the circuit breaker.
Ensure that there are no obstructions that impair the operation of the front panel line-
supply circuit breaker(s).
CAUTION! Do not obstruct the airflow through the amplifier.
The cooling airflow is drawn in through the front and exhausted at the rear. If this
airflow is obstructed, overheating of the amplifier may occur.
CAUTION! Do not operate the amplifier outside its specification.
This may cause the amplifier to malfunction or be damaged.
WARNING! Do not touch the exterior of the amplifier (rack mount version)
when in use.
The top and side panels of the amplifier can get hot during use, especially on high
power models.
CAUTION! Periodically replace the air-intake filters.
Operating the amplifier with the air filters dirty may cause the amplifier to overheat.
or
The appropriate lifting practices should be observed during transportation, installation,
or removal of the amplifier from its mounting position.
WARNING!
Use the safety interlock facility within danger areas.
Any area where personnel may come into direct contact with high power RF, or be
exposed to non-ionising radiation, should be designated as a danger area. A barrier
should be established around any such area, with a switch in place when the barrier is
broken. This switch can be linked to the safety interlock BNC connector on the
amplifier, thus disabling the amplifier when the barrier is breached.
It is the responsibility of the operator to ensure that the working environment is safe.
The 'safety interlock' feature is provided to assist the purchaser in establishing such a
'safe' area.
CBA Manual: H012161 Rev: 3
CAUTION!
Exercise caution when lifting.
8