Once pressed the OPRT/STBY button
will illuminate green. This will indicate the
DC power supply has energised
supplying voltage to the power modules
and the amplifier is in, Operate mode
(RF On)
5.6
FLT/RST
The Fault/Reset (FLT/RST) will illuminate
red when a fault is detected. Once the
fault is removed/fixed depressing the
FLT/RST will clear the fault indication so
that normal operation of the amplifier can
resumed.
5.7
LOC/RMT
When the amplifier receives a remote
command the LOC/RMT will illuminate
green. Depressed the button will restore
the amplifier to local operation
5.8
Gain Control
The gain control button allows for gain
adjustments over the entire operating
frequency of the amplifier over a range of
30dB in 100 steps via the touch screen.
255 steps via the remote command
function.
CBA Manual: H012161 Rev: 3
14