7.3

RF output N-Type or 7/16 (Model Dependent)

The nominal RF output impedance of the amplifier is 50 ohms, but it will safely drive a
load with an input impedance other than 50 ohms (resistive or reactive), but will deliver
less power. Refer to the specification sheet for details of RF output power.
7.4

Sample Ports, N-TYPE Female

These allow monitoring of both the incident power (P
low level.
The nominal output impedance is 50 ohms, and each output should be connected to a
50Ω test system or terminated with 50Ω load supplied with the amplifier.
Nominal Output
Impedance (ohms)
50
50
The above parts can be supplied as spares or replacement items. The part number
must be quoted when ordering.
7.5

Line supply input connector

The CBA series power supply is equipped with a IEC or Neutrik Powercon inlet for
single phase models and a high current 3 phase / 5 wire MS connector for high power
models. The amplifier systems are supplied with mating power cords.
Rear Panel Single Phase
IEC
Note: Mains inlet connectors are model dependent.
CBA Manual: H012161 Rev: 3
WARNING!
High RF voltages can occur on the inner conductor of the RF-out
connector, which could cause RF burns if touched. Do not expose
the centre pin to static discharge.
Amplifier Power
Level (Watts)
<700
> 700
Rear Panel Single Phase
Neutrik 'Powercon'
17
) and the reflected power (P
i
Nominal Output
Flatness
Level (dBc)
40
50
3 Phase 5 Wire MS Connector
) at
r
(dB)
+/- 3
+/- 3