Falcon E3901i Installation And Servicing Instructions

Falcon E3901i Installation And Servicing Instructions

Induction boiling tables

Advertisement

Quick Links

E3901i / E3902i
Induction Boiling Tables
INSTALLATION and
SERVICING INSTRUCTIONS
IMPORTANT
The installer must ensure that the installation of the appliance is in conformity with these instructions
and National Regulations in force at the time of installation. Particular attention MUST be paid to –
BS7671 IEE Wiring Regulations
Health and Safety At Work Act
Electricity at Work Regulations
Fire Precautions Act
WARNING
READ THESE INSTRUCTIONS BEFORE INSTALLING THIS APPLIANCE.
BEFORE ATTEMPTING ANY MAINTENANCE, ISOLATE THE APPLIANCE AT THE MAINS
ISOLATING SWITCH AND TAKE STEPS TO ENSURE THAT IT CANNOT BE INADVERTENTLY
SWITCHED ON.
IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING
AND COMMISSIONING THIS APPLIANCE. FAILURE TO COMPLY WITH THE SPECIFIED
PROCEDURES MAY RESULT IN DAMAGE AND NEED FOR A SERVICE CALL.
On completion of the installation these instructions should be left with the Engineer-in-Charge for
reference during servicing. In addition, the Users Instructions should be handed to the User, having
had a demonstration of the operation and cleaning of the appliance.
PREVENTATIVE MAINTENANCE CONTRACT
In order to maintain maximum performance from this unit we would recommend that a Maintenance
Contract be arranged with SERVICELINE. Regular visits can be arranged to adjust, maintain and
repair the unit. A quotation will be given upon request to the contact numbers below.
WEEE Directive Registration No. WEE/DC0059TT/PRO
At end of unit life, dispose of appliance and any replacement
parts in a safe manner, via a licenced waste handler.
Units are designed to be dismantled easily and recycling of all
material is encouraged whenever practicable.
Falcon Foodservice Equipment
HEAD OFFICE AND WORKS
Wallace View, Hillfoots Road, Stirling. FK9 5PY. Scotland.
SERVICELINE CONTACT
Phone: 01438 363 000
Fax: 01438 369 900
T100803 Ref. 3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the E3901i and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Falcon E3901i

  • Page 1 E3901i / E3902i Induction Boiling Tables INSTALLATION and SERVICING INSTRUCTIONS IMPORTANT The installer must ensure that the installation of the appliance is in conformity with these instructions and National Regulations in force at the time of installation. Particular attention MUST be paid to –...
  • Page 2 IMPORTANT INFORMATION Warranty Policy Shortlist Warranty does not cover :- Correcting faults caused by incorrect installation of a product. Where an engineer cannot gain access to a site or a product. Repeat commission visits. Replacement of any parts where damage has been caused by misuse. Engineer waiting time will be chargeable.
  • Page 3: Section 1 - Installation

    Weight Model (mm) (mm) (mm) (kg) regulations. E3901i Induction Access to terminal block is gained by removing the Table on legs access panel close to cable entry gland on rear panel. E3901i Induction Table on castors E3902i Induction 1.5 ELECTRICAL RATINGS...
  • Page 4: Section 3 - Servicing And Conversion

    2.4 INSTRUCTION TO USER Remove two wires connected to LED. After installation and commissioning is completed, please Remove control knob. hand User Instructions to user and ensure that the Undo fixings that secure control to panel. person(s) responsible understand the instructions Remove associated LED (if required).
  • Page 5: Section 4 - Spares

    Replace and re-assemble in reverse order. SUPPLY PROTECTION DEVICE Refer to wiring diagram A in Section 5 of this manual. The appliance is fitted with a miniature circuit breaker (MCB) as additional protection against over current. 3.7 TO REPLACE SWITCH CABLES If unit fails to operate or show any operational indicators, Access cables as detailed in Section 3.6.
  • Page 6 Code Cause Action U / E Error Use of unsuitable pan material Use suitable pan. User detection Re-set required Switch unit off for 10 seconds, then on. Engineer error Defective coil Engineer required. Re-set required Switch unit off for 10 seconds, then on. User No coil current...
  • Page 7 Code Cause Action U / E Error Re-set required Switch unit off for 10 seconds, then on. User Communication error Engineer Failure on LIN or CAN-Bus Engineer required. Re-set required Switch unit off for 10 seconds, then on User Initialisation error Software failed when initialising Wait.

This manual is also suitable for:

E3902i

Table of Contents