Installer manual Siata V132 - SFE - Commissioning
Brine tank softeners
Backwash the conditioner and add the required amount of hypochlorite solution to the well of the
brine tank. The brine tank should have water in it to permit the solution to be carried into the
conditioner.
Proceed with the normal regeneration.
Calcium hypochlorite
Calcium hypochlorite, 70% available chlorine, is available in several forms including tablets and
granules. These solid materials may be used directly without dissolving before use.
Dosage
Measure two grains (~ 3 mL [0.1 ounce]) per 28.3 L (1 cubic foot).
Brine tank softeners
Backwash the conditioner and add the required amount of hypochlorite to the well of the brine tank.
The brine tank should have water in it to permit the chlorine solution from being carried into the
conditioner.
Proceed with the normal regeneration.

7.2.3. Electro chlorination

Valves or systems already equipped with an electrochlorinator device or system are supposed to be
sanitized during the brine draw phase.