A
Use
and
to edit this parameter.
B
Press
to validate and switch to the next parameters.
Interval time between regenerations
Set the interval time (hours) between regenerations.
A
Note
This parameter is displayed after the regeneration start mode only if an interval start has
been selected (SH:03).
A
Use
and
to edit this parameter.
B
Press
to validate and switch to the next parameters.
Volumetric meter K factor
Set the volumetric meter K factor. The parameter is composed of the
integer part and of the decimal part, separated by the decimal point.
Set this parameter to 14.0 for Siata V132.
A
Note
This parameter is displayed after the regeneration start mode only if a volume start has
been selected (SH:01 or SH:02).
A
Use
and
to edit this parameter.
B
Press
to validate and switch to the next parameters.
Volume to be treated before starting regeneration
Set the volume (liters) to be treated before starting the regeneration.
Thousands and hundreds are modified first; once they are correctly
set, press
to switch to the tenths and units setting.
A
Note
This parameter is displayed after the regeneration start mode only if a volume start has
been selected (SH:01 or SH:02).
A
Use
and
to edit this parameter.
B
Press
to validate and switch to the next parameters.
The following formula is used to calculate the volume of treatable water (in liters) between two
subsequent regenerations:
V
= [(L.xxx) x (C.xx) x 1000] / [(d.xxx) - (do.xx)]
treatable water
Ref. MKT-IM-003 / B - 19.04.2017
Installer manual Siata V132 - SFE - Programming
47 / 88