Advanced Settings - Grandstream Networks GSC35 Series User Manual

Hide thumbs Also See for GSC35 Series:
Table of Contents

Advertisement

Advanced Settings

Security Settings
Check Domain
Certificates
Validate Certification
Chain
Block any number of leading digits 1900 or add prefix 1617 for any dialed
7-digit numbers
Example 3: {1xxx[2-9]xxxxxx | <2=011>x+}
Allow any number with leading digit 1 followed by a 3-digit number, followed
by any number between 2 and 9, followed by any 7-digit number OR allow
any length of numbers with leading digit 2, replacing the 2 with 011 when
dialed.
3. Default: Outgoing – { x+ | \+x+ | *x+ | *xx*x+ }
Allow any number of digits, OR any number with a leading +, OR any
number with a leading *, OR any number with a leading * followed by a 2-
digit number and a *.
Example of a simple dial plan used in a Home/Office in the US:
{^1900x. | <=1617>[2-9]xxxxxx | 1[2-9]xx[2-9]xxxxxx | 011[2-9]x. | [3469]11 }
Explanation of example rule (reading from left to right):
^1900x. – prevents dialing any number started with 1900
<=1617>[2-9]xxxxxx – allow dialing to local area code (617) numbers
by dialing 7 numbers and 1617 area code will be added automatically
1[2-9]xx[2-9]xxxxxx |- allow dialing to any US/Canada Number with 11
digits length
011[2-9]x. – allow international calls starting with 011
[3469]11 – allow dialing special and emergency numbers 311, 411, 611
and 911
Note: In some cases, where the user wishes to dial strings such as *123 to
activate voice mail or other applications provided by their service provider,
the * should be predefined inside the dial plan feature. An example dial plan
will be: {*x+} which allows the user to dial * followed by any length of
numbers.
Sets the device to check the domain certificates if TLS/TCP is used for SIP
Transport. The default setting is "No".
Configures whether to validate certification chain, when TLS/TCP is
configured for SIP Transport. If this is set to "Yes", phone will validate server
against the new certificate list. The default setting is "No".
GSC35XX Series User Manual
Version 1.0.0.15
P a g e
|
46