4 Electrical and Environmental Features
4.1 Absolute Maximum Ratings
The table gives the maximum electrical characteristics of the module interface signals.
Note: Using the G510 module beyond these conditions may result in permanent damage to the module.
Parameter
BATT Supply
Digital Input Signals
Analog Input Signals (Audio
interfaces)
4.2 Environmental Specifications
The table gives the environmental operating conditions of the G510 module.
Note:Using the G510 module beyond these conditions may result in permanent damage to the module.
Parameter
Operating Temperature
Storage Temperature
ESD
4.3 Application Interface Specifications
The table summarizes the DC electrical specifications of the application interface connector signals.
Note:Interface signals that are not used by the customer application must be left unconnected. The
G510 Hardware User Manual
Conditions
module powered on
VDD Domain
module powered on
Conditions
(Contact)
Antenna connector
(Air)
Antenna connector
Min
Max
-0.2
4.5
-0.2
3.3
-0.2
2.75
Min
Max
-40
85
-40
85
± 8
± 15
Unit
V
V
V
Unit
°C
°C
KV