TECHNICAL DESCRIPTION
10 Power Supply
62 must be internally powered by 3.6 VDC ( 0,1VDC) on terminals 60(+) and 61(-). This is obtained
®
MULTICAL
using one of the following supply modules:
MULTICAL
Supply
Battery D-cell
230 VAC high power isolated SMPS
24 VAC high power isolated SMPS
230 VAC supply module with transformer
24 VAC supply module with transformer
The above mentioned supply modules are included in the comprehensive type test, to which MULTICAL
been subjected. Within the framework of the type approval, the CE-declaration and the manufacturer's guarantee
no other types of power supplies than the ones listed above can be used.
®
ULTRAFLOW
24 will be powered by the same supply.
10.1 Built-in D-cell lithium battery
When power supplied by a battery MULTICAL
battery is mounted in the right side of the connection base with the red wire connected to terminal 60(+) and the
black wire to terminal 61(-). The battery is easily replaced using a screwdriver.
The battery lifetime depends on the temperature, to which the battery is exposed, as well as the selected
application for the meter.
MULTICAL
(battery temperature 30 C)
MULTICAL
(battery temperature 45 C)
The above-mentioned battery lifetimes apply to standard installations. The battery lifetime is reduced by:
-
Warm ambient temperature
-
Connection of data modules
-
Frequent data communication
Please contact Kamstrup A/S for further information.
48
®
62
Type 62-
®
62 uses a lithium D-cell (Kamstrup type 66-00-200-100). The
Application (temperature)
®
62 mounted on a wall
®
62 mounted on flow sensor
5512-1036 GB/07.2012/Rev.B1
Z
2
3
4
7
8
Battery lifetime
12+1 years
10 years
®
MULTICAL
62
00
®
62 has