TECHNICAL DESCRIPTION

10 Power Supply

MULTICAL
®
61 must be internally powered by 3.6 VDC ( ± 5%) on terminals 60(+) and 61(-). This is obtained using
one of the following supply modules:
MULTICAL
Supply
Battery D-cell
230 VAC supply module with transformer
24 VAC supply module with transformer
The three above-mentioned supply modules are included in the comprehensive type test, to which MULTICAL
has been subjected. Within the framework of the type approval, the CE-declaration and the manufacturer's
guarantee no other types of power supplies than the ones listed above can be used.
®
ULTRAFLOW
24 will be powered by the same supply.

10.1 Built-in D-cell lithium battery

When supplied by a battery MULTICAL
mounted in the right side of the connection base with the red wire connected to terminal 60(+) and the black wire
to terminal 61(-). The battery is easily replaced using a screwdriver.
The battery lifetime depends on the temperature, to which the battery is exposed, as well as the selected
application for the meter.
MULTICAL
(battery temperature < 30 ° C)
MULTICAL
(battery temperature < 45 ° C)
The above-mentioned battery lifetimes apply to standard installations. The battery lifetime is reduced by:
-
Warm ambient temperature
-
Connection of data modules
-
Frequent data communication
Please contact Kamstrup A/S for further information.
40
®
61
Type 67-
®
61 uses a lithium D-cell (Kamstrup type 66-00-200-100). The battery is
Application (temperature)
®
61 mounted on a wall
®
61 mounted on flow sensor
5512-622 GB/01.2011/Rev. E1
Z
2
7
8
Battery liftetime
12 years
10 years
®
MULTICAL
61
0
®
61

Advertisement