10.2. Wiring Guide for RS-232 Data Transmission
Room Automation Panel is built with 3-pole Phoenix connector. See
the below examples of connecting to a DCE (Data Circuit-terminating
Equipment) or a DTE (Data Terminal Equipment) type device:
Lightware device and a DCE
D-SUB 9 - Phoenix
TX RX
5
1
9
6
2: TX data transmit
3: RX data receive
5: Ground
INFO: The RAP-B511 series works as a DCE unit according to its
pin-out.
10.3. Factory Default Settings
Parameter
Button enabled
Lightware device and a DTE
Operation mode
D-SUB 9 - Phoenix
Interaction state
EnabLED
TX RX
LED function for True state
LED function for False state
Button LED lowbright level
Button LED highbright level
1
5
IP address
6
9
Subnet mask
2: TX data receive
3: RX data transmit
Static gateway
5: Ground
DHCP
LW2 port number
LW3 port number
HTTP port number
Control protocol
Baud rate
Databits
Parity
Stopbits
Operation mode
Command injection port nr.
Recognizer delimiter
Recognizer Timeout
Recognizer Active property timeout
RAP-B511 series – User's Manual
Setting/Value
Button settings
true
0
true
true
off
off
2
5
Network settings
192.168.0.100
255.255.255.0
192.168.0.1
Disabled
10001
6107
80
RS-232 settings
LW2
57600
8
No
1
Command Injection
8001
0D0A
0 (disabled)
50
Parameter
IR port settings
Command injection status
Enabled
Command injection input port nr.
9001
GPIO port settings
Output level
High
Direction
Input
70
Setting/Value