5. Software Control - Lightware Device Controller
5.6. Event Manager
The feature means that the device can sense changes on its ports and able to react
according to the pre-defined settings. The development idea of the Event manager is
based on users' feedbacks. In many cases internal events are necessary to display
but it is not easy when the device is hard to access (e.g. built under the desk).
The Event manager can be configured to perform an action if a condition has been detected. E.g. the desired
setup is that after a certain type of IR signal has been detected on S1 port, the device send an RS-232
message. The settings can be done via the LDC in the Control/Events tab, or by LW3 protocol commands.
Configurable events number depends on the device what you are using actually.
Numerous new ideas and requests have been received in connection with the features and settings of the
Event manager since the first release. Therefore, the user interface has been re-designed and many new
functions implemented. The Event editor can be opened by pressing the Edit button at each Event.
There is a grey bar on the left of the Event panel in each line. If a condition and an action are set and the Event
is enabled, the bar is displayed in green.
Control menu, Event Manager tab
RAP-B511 series – User's Manual
5.6.1. Event Manager in the RAP-B511
The functionality of the Room Automation Panel based on the Event Manager. UI config page provides an
interface where the events can be set easily and they are saved in the Event Manager. Events from the UI
config page listed backwards (e.g. first event is saved to the E300 slot).
These events are identified by the event name property, which refers to the button (e.g. UIConfig_B11_1) or
the rotary position (e.g. UIConfig_ROT_13).
ATTENTION! Rename the Events from the UI Config page is highly not recommended!
When one of these events is opened to Edit in the Event Manager, the warning message appears:
The tables below summarize the availablility of the conditions and actions of the RAP-B511.
Conditions
Launch configuration from...
Button press /button release
Rotary turn / rotary press
Real-time clock
Infra detector
RS-232 recognizer
GPIO input level change
Actions
Launch configuration from...
Button LEDs
Button Interaction State
Ethernet
RS-232
GPIO
 The setting is available and recommended to do the configuration from this menu.
The setting is not available in that menu.
Only for advanced users! The setting is available in the Event Manager, but doing the configuration is
highly recommended from the UI config menu.
...UI config menu

...Event Manager

...UI config menu
...Event Manager