7.3.1. Query the Product Name
The name of the product is a read-only parameter and cannot be
modified.
Command and Response
Ý GET·/.ProductName
pr·/.ProductName=<product_name>
Ü
Example
Ý GET /.ProductName
Ü pr /.ProductName=RAP-B511-EU-K
7.3.2. Set the Device Label
ATTENTION! The device label can be changed to a custom text in
the
Status
tab of the LDC software. This writable parameter is not
the same as the ProductName parameter.
Command and Response
Ý SET·/MANAGEMENT/
LABEL.DeviceLabel=<custom_name>
pw·/MANAGEMENT/LABEL.DeviceLabel=<custom_name>
Ü
The Device Label can be 31 character length and ASCII characters are
allowed. Longer names are truncated.
Example
Ý SET /MANAGEMENT/LABEL.DeviceLabel=RAP-B511
Ü pw /MANAGEMENT/LABEL.DeviceLabel=RAP-B511
7.3.3. Query the Serial Number
Command and Response
Ý GET·/.SerialNumber
pr·/.SerialNumber=<serial_nr>
Ü
Example
Ý GET /.SerialNumber
Ü pr /.SerialNumber=00009865
RAP-B511 series – User's Manual
7.3.4. Query the Firmware Version
Command and Response
Ý GET·/SYS/MB.FirmwareVersion
pr·/SYS/MB.FirmwareVersion=<firmware_version>
Ü
Example
Ý GET /SYS/MB.FirmwareVersion
Ü pr /SYS/MB.FirmwareVersion= v1.0.1b2
7.3.5. Resetting the Device
The device can be restarted – the current connections (LAN, RS-232
or USB) will be terminated.
Command and Response
Ý CALL·/SYS:reset()
Ü mO·/SYS:reset=
Example
Ý CALL /SYS:reset()
Ü mO /SYS:reset=
7.3.6. Restore the Factory Default Settings
Command and Response
Ý CALL·/SYS:factoryDefaults()
Ü mO·/SYS:factoryDefaults=
Example
Ý CALL /SYS:factoryDefaults()
Ü mO /SYS:factoryDefaults=
The device is restarted, current connections are terminated, and the
default settings are restored. See the complete list in the
Default Settings
section.
7.3.7. Enable PoE
Command and Response
SET·/SYS/MB/POE.PoeEnabled=<PoE_status>
Ý
pw·/SYS/MB/POE.PoeEnabled=<PoE_status>
Ü
Parameters
<PoE_status>
True: PoE sending is enabled on P2 Ethernet port.
False: PoE sending is disabled on P2 Ethernet port.
Example
Ý SET /SYS/MB/POE.PoeEnabled=true
Ü pw /SYS/MB/POE.PoeEnabled=true
INFO: The RAP-B511 sends PoE when the connected device is also
PoE-compatible.
Factory