ProMinent DULCOflex DFBa Series Operating Instructions Manual page 25

Peristaltic pump
Table of Contents

Advertisement

Fig. 3: Squeezing the hose
1
Normal shape of hose
2
Excessive squeezing (increased wear and tear
on the pump and hose)
3
Perfect squeezing
4
Insufficient squeezing (medium backflowing in
the cavity will destroy the hose within a short
period of time)
Tab. 3: DFBa 010 / Number of spacer plates of 0.5 mm thickness (except Norprene
rpm
0-19
bar
0.5
1
2.0
1
4.0 *
2
6.0
2
8.0
3
* Delivery state
Tab. 4: DFBa 010 / Number of spacer plates of 0.5 mm thickness (Norprene
rpm
0-19
bar
0.5
5
2.0 *
5
* Delivery state
4
The spacer plates are factory-fitted. You can adapt the number of
spacer plates to the actual operating conditions in accordance with
the following table.
20-39
1
1
1
2
2
20-39
5
5
Transport, storage, assembly and Installation
1
3
40-59
60-79
1
1
1
1
1
1
2
®
40-59
60-79
5
5
5
5
2
P_DX_0021_SW
®
and TYGON
®
):
80-99
1
1
1
and TYGON
):
®
80-99
5
5
25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents