Removing End Caps - Emerson EL-O-Matic F Series Installation, Operation And Maintenance Manual

Rack and pinion pneumatic actuators
Hide thumbs Also See for EL-O-Matic F Series:
Table of Contents

Advertisement

Installation, Operation and Maintenance Manual
DOC.IOM.EF.EN Rev. 6
8.1

Removing End Caps

1.
Figure 17
10
The above end caps (2) are for Actuator sizes 25, 40, 65 and 100.
End caps (2) for Actuator sizes 150 and larger will have flat end caps (see below).
Disassembly
For Double-acting actuators, do the following:
a.
Loosen the screws (10) of the end caps (2).
b.
Remove the o-ring (14) and "B" port seal (16). Discard these parts.
Double-Acting End Caps Removal
2
2
14
16
2
Section 8: Disassembly
September 2015
2
10
14
25