Removing End Caps (Sizes 25 To 600) - Emerson EL-O-Matic F-Series Installation, Operation And Maintenance Manual

Rack and pinion pneumatic actuators
Hide thumbs Also See for EL-O-Matic F-Series:
Table of Contents

Advertisement

Installation, Operation and Maintenance Manual
DOC.IOM.EF.EN Rev. 7
8.1

Removing End Caps (Sizes 25 to 600)

1.
Figure 17
Double acting end caps (6) are fitted with a white warning sticker. Spring return end
caps (5) are fitted with a black warning sticker.
The above end caps (5) are for actuator sizes 25, 40, 65 and 100.
End caps (6) for double acting actuator sizes 150 and larger will have flat end caps.
Disassembly
For Double-acting actuators, do the following:
a.
Remove the screws (8) and washers (10) of the end caps (6).
b.
Remove the o-ring (11) and "B" port seal (2). Discard these parts.
Double-Acting End Caps Removal
8
10
6
6
11
11
2
5
Section 8: Disassembly
September 2017
6
8
10
2
27

Hide quick links:

Advertisement

Table of Contents
loading