Mounting Of Control And Feedback Accessories - Emerson EL-O-Matic F Series Installation, Operation And Maintenance Manual

Rack and pinion pneumatic actuators
Hide thumbs Also See for EL-O-Matic F Series:
Table of Contents

Advertisement

Installation, Operation and Maintenance Manual
DOC.IOM.EF.EN Rev. 6
5.
Table 8.
Actuator Size
12
25
40, 65, 100
150, 200, 350
600
950, 1600, 2500,
4000
6.
Figure 12
"In Line mounting"
4.6

Mounting of control and feedback accessories

Solenoid valve and or switch boxes can now be mounted to the actuator. Check
the instructions as shipped with these components for installation, operating and
maintenance instructions.
We recommend to test-cycle the complete assembly to check correct operation.
Installation
Install the actuator to the bracket. Tighten all bolts and apply the correct torque
(refer to Table 8).
Bottom flange torque values
ISO Pattern
F04
F03 inner pattern
F05 outer pattern
F05 inner pattern
F07 outer pattern
F07 inner pattern
F10 outer pattern
F10 inner pattern
F12 outer pattern
When required, mount or adjust the visual indicator (22).
Indicator mounting
22
Torque (Nm)
Thread
Min.
Max.
M6
4.5
5
M5
2.0
3.0
M6
4.5
5.0
M6
4.5
5.0
M8
10.5
12.5
M8
10.5
12.5
M10
21.0
24.5
M10
21.0
24.5
M12
34.5
43.0
"Across Line mounting"
Section 4: Installation
September 2015
Torque (lbf.ft)
Thread
Min.
Max.
10-24UNC
3.3
3.7
10-24UNC
1.5
2.2
1/4"-20
3.3
3.7
1/4"-20
3.3
3.7
5/16"-18
7.7
9.2
5/16"-18
7.7
9.2
3/8"-16
15.5
18.1
3/8"-16
15.5
18.1
1/2"-13
25.4
31.7
22
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents