Error
Display
codes
E5
Empty
O
wastewa-
ter.
E8
Filling pro-
O
cedure
please wait
E10
Seclect
O
rinsing pro-
gramme
E11
Heating
O
E12
Service
O
fault: E12
E13
Service
O
fault: E13
E14
Service
O
fault: E14
E15
Service
O
fault: E15
E16
Service
O
fault: 16
Fault
Display on, pump without function
O
X
X
O
O
Cause
Performance electronics
Check the fuse.
Cause
O
O
O
Correction
Replace defective fuse.
Fuse 6.3A (slow-blow)
English 5.906-590.0 Rev. 01 (05/17)
Correction
Insert the wastewater con-
tainer properly and lock it.
Empty the wastewater res-
ervoir.
Check the float in the tank
for mobility.
Note
Information only appears
upon the initial filling.
Note
Information appears after
operation with detergent.
No steam operation possi-
ble.
Note
Information only appears
upon the initial filling.
Check the connector plug
"hand tool" on the device
for proper seating.
The connector plug "hand
tool" on the device must be
completely dry.
Check the connector plug
"hand tool" on the device
for proper seating.
The connector plug "hand
tool" on the device must be
completely dry.
Actuate reset button µc-
card.
Note
Steam boiler should be
descaled.
See chapter:
Descaling steam boiler
Note
Steam boiler must be
descaled.
See chapter:
Descaling steam boiler
Check fan for soiling or
damage.
Check the connector.
Check plug contacts on the
power electronics (power
card).
Check ribbon cable that
connects the power card
with μc-card.
If defective, exchange μc-
card.
Note
Further tests see:
Table of measurement values
67