  • Page 1 05.2019 New as of: inLab Profire Operating Instructions English...
  • Page 2: Table Of Contents

    Table of contents Dentsply Sirona Operating Instructions inLab Profire Table of contents General data ......................Dear Customer,.................... Contact data....................General information about these operating instructions ......Limitation of liability..................Warranty ...................... Structure of the document................1.6.1 Identification of the danger levels ..........
  • Page 3 Dentsply Sirona Table of contents Operating Instructions inLab Profire 5.5.8 My programs .................. 5.5.9 Material change ................Data transmission via USB stick ..............5.6.1 Restarting the unit................5.6.2 ON/OFF button on the touch display ..........Explanation of the symbols ................
  • Page 4: General Data

    1.1 Dear Customer, Operating Instructions inLab Profire General data Dear Customer, Thank you for purchasing your inLab Profire high-temperature furnace from Dentsply Sirona. It will support you with your work for many years, as it was developed and built with state-of-the-art technology.
  • Page 5: Limitation Of Liability

    Dentsply Sirona 1 General data Operating Instructions inLab Profire 1.4 Limitation of liability Online portal for technical documents We have set up an online portal for the Technical Documents at www.dentsplysirona.com/manuals. From here, you can download these Operating Instructions along with other documents. Please complete the online form if you would like a hard copy of a particular document.
  • Page 6: Structure Of The Document

    1 General data Dentsply Sirona 1.6 Structure of the document Operating Instructions inLab Profire Structure of the document 1.6.1 Identification of the danger levels To prevent personal injury and material damage, please observe the warning and safety information provided in these operating instructions.
  • Page 7: Safety Instructions

    CAUTION Risk due to incorrect setup The inLab Profire high-temperature furnace may only be set up in dry rooms and must never be in contact with any liquids. Furniture items and other equipment in the vicinity of the furnace must not contain any explosive, flammable or easily ignitable materials.
  • Page 8: Dentsply Sirona

    IMPORTANT In the event of any work on the inLab Profire high-temperature furnace, personal protective equipment must be worn to prevent accidents and harm to health.
  • Page 9: Dentsply Sirona

    Operating Instructions inLab Profire WARNING Risk of burns due to hot surfaces! Hot surfaces arise at some points on the inLab Profire high- temperature furnace. Use the necessary caution around the furnace, especially when the furnace is operated for extended periods.
  • Page 10: Dentsply Sirona

    2 Safety instructions Dentsply Sirona Operating Instructions inLab Profire IMPORTANT Always dispose of the insulating material in a closed container (see also the section on "Disposal"). WARNING Risk of burns due to objects falling out As there is a serious risk of burns in this case, it is essential to install a fire-proof table and floor covering.
  • Page 11: Technical Description

    3.1 Description of the furnace Technical description Description of the furnace The inLab Profire high-temperature furnace is used for processing sinterable ceramics and cobalt-chromium. The product to be sintered is placed in the sintering tray and positioned on the bearing plate. After entering the heating parameters and pressing the start symbol, the electrically powered furnace door closes and the heating operation begins.
  • Page 12: Certification

    Further products which are connected to this unit must also bear the CE mark. These products must be tested according to the applicable standards. We declare conformity for the inLab Profire ceramic sintering furnace on the basis of the following standards: ● Safety: EN 61010-1:2010 and EN 61010-2-010:2014 ●...
  • Page 13: Technical Data

    Dentsply Sirona 3 Technical description Operating Instructions inLab Profire 3.5 Technical data Technical data Model designation: inLab Profire Version Zirconia only Zirconia + metal Zirconia only Zirconia + metal 13  A 13  A 15  A 15  A Type of protection against elec-...
  • Page 14: Rating Plate

    3 Technical description Dentsply Sirona 3.6 Rating plate Operating Instructions inLab Profire Rating plate Machine type/designation Reference number Dentsply Sirona Operating voltage Serial number Line frequency Year of manufacture Current consumption Manufacturer specifications CE mark EAC mark 67 15 887 D3770...
  • Page 15: Configuration

    Operating Instructions inLab Profire 4.1 Installation site Configuration Installation site The inLab Profire high-temperature furnace is designed as a tabletop unit. For stability, a flat, horizontal, and fire-proof surface of at least 50 cm x 60 cm, which can support loads of up to 80 kg, is recommended.
  • Page 16: Dentsply Sirona

    4 Configuration Dentsply Sirona 4.1 Installation site Operating Instructions inLab Profire Ensure an adequate distance between the rear of the unit and the wall in particular. ≥ 100 mm CAUTION Risk of ignition! Igniting of the floor covering due to hot shattering product tray.
  • Page 17: Dentsply Sirona

    Dentsply Sirona 4 Configuration Operating Instructions inLab Profire 4.1 Installation site CAUTION Risk of injury posed by carrying the furnace! Physical strain / back complaints due to the furnace's heavy dead weight. Injuries due the furnace falling down. ➢ Use at least two people to carry/move the furnace (max. 30 kg carrying capacity per person).
  • Page 18: Electrical Connection

    Electrical connection Building installation The following electrical installation requirements are to be fulfilled for the inLab Profire high-temperature furnace: ● The furnace requires a separate electric circuit. ● The electrical building installation must be protected by a type K/Z circuit breaker with a rating of at least 16 A (other fuse types according to the country of use).
  • Page 19: Dentsply Sirona

    Dentsply Sirona 4 Configuration Operating Instructions inLab Profire 4.2 Electrical connection Device Do not adjust the line voltage! The unit automatically adjusts to the line voltage. DANGER Electrical power! Risk of fatality posed by electric shock. ➢ Do not touch live cables and components with wet hands.
  • Page 20: Operation

    5 Operation Dentsply Sirona 5.1 Controls Operating Instructions inLab Profire Operation Controls Front panel Basic unit Control panel Start button for the display Status display Door insulation / base carrier Door insulation bearing Sintering tray Rear side Rating plate Main switches and connections 67 15 887 D3770 D3770.201.01.02.02    05.2019...
  • Page 21: Dentsply Sirona

    Dentsply Sirona 5 Operation Operating Instructions inLab Profire 5.1 Controls Main switch ON / OFF Power connection Argon port USB port (voltage supply: 5 V; rated current: 500 mA) LAN port Main fuse F1 Main fuse F2 67 15 887 D3770 D3770.201.01.02.02    05.2019...
  • Page 22: Connecting The Argon Supply

    The argon flow is set by default in the factory and is approx. 1l/ minute. 1. Connect the connecting hose included in the scope of supply with the inLab Profire high-temperature furnace (including metal) to the argon port of the furnace and the argon supply (gas canister).
  • Page 23: Burning-In Insulation And Sintering Aids

    Dentsply Sirona 5 Operation Operating Instructions inLab Profire 5.4 Inserting the door insulation 3. Press the lift button to open the door. 4. Insert the door insulation (see Inserting the door insulation  [→ 23]). IMPORTANT At temperatures below 15°C (e.g. following transport), allow the unit to stand for approx.
  • Page 24: Explanation Of The Main Screens

    5 Operation Dentsply Sirona 5.5 Explanation of the main screens Operating Instructions inLab Profire Explanation of the main screens 5.5.1 System test After starting the unit, a system test is first performed. Please wait during this phase and do not switch the unit off.
  • Page 25: Main Menu

    Dentsply Sirona 5 Operation Operating Instructions inLab Profire 5.5 Explanation of the main screens 5.5.2 Main menu The following menu items are available for selection on the "Main menu" screen: ● "Favorites" ● "Programs" ● "Settings" ● "Service" The "Service" area is only of relevance to service engineers.
  • Page 26: New Program

    5 Operation Dentsply Sirona 5.5 Explanation of the main screens Operating Instructions inLab Profire 5.5.6 New program You can switch to the "New program" screen via the "Programs" and "My programs" screens. You can create new programs here. 1. To create a new program, tap on the first field "rate of increase" in the next free line.
  • Page 27: Service Programs

    Dentsply Sirona 5 Operation Operating Instructions inLab Profire 5.5 Explanation of the main screens 5.5.7 Service programs Tip: Backing up the programs is recommended. If you have entered your individual programs, it is recommended to back up the programs to an external storage medium.
  • Page 28: Material Change

    5 Operation Dentsply Sirona 5.6 Data transmission via USB stick Operating Instructions inLab Profire 5.5.9 Material change The "Material" screen is displayed to you if you are switching from a zirconia to an argon program. Please replace the sintering tray system and make sure that the gas supply is secured.
  • Page 29: Restarting The Unit

    Dentsply Sirona 5 Operation Operating Instructions inLab Profire 5.7 Explanation of the symbols 5.6.1 Restarting the unit To perform a restart, switch the unit off at the rear and wait approx. 30 seconds until the green LED no longer lights up or flashes.
  • Page 30 5 Operation Dentsply Sirona 5.7 Explanation of the symbols Operating Instructions inLab Profire Move backwards Tap on the button to go back to the previous step. Start program Tap on the button to start the selected program. Stop Tap on the button to stop the running process.
  • Page 31: Dentsply Sirona

    Dentsply Sirona 5 Operation Operating Instructions inLab Profire 5.7 Explanation of the symbols Pre-drying active (45 minutes) This button is displayed if pre-drying has been acti- vated. In this instance, the pre-drying time is 45 minutes. Tap once more on the button "Activate pre-drying"...
  • Page 32: Dentsply Sirona

    5 Operation Dentsply Sirona 5.7 Explanation of the symbols Operating Instructions inLab Profire Interaction symbols Confirm Tap on the button if you want to perform the dis- played operation. Reject Tap on the button if you do not want to perform the displayed operation.
  • Page 33: Sintering Aids

    Serious error (2-digit error code) Automatic process stop / Work is very unlikely to be of use Sintering aids IMPORTANT Only use sintering aids approved by Dentsply Sirona. You can find usage tips in the information pamphlet of the respective sintering aid. 5.8.1...
  • Page 34: Preparations For Sintering Zro2

    Positioning the sintering tray in the inLab Profire ● Position the split support disc centrally on the door insulation. A recess is present for the tip of the guide pin.
  • Page 35: Dentsply Sirona

    The tray (2) with the split support disc should be positioned at the end of the fork. Positioning a second sintering tray in the inLab Profire - only for classic mode ● Position an unsplit support disc on the first sintering tray. You can then place the second sintering tray on it.
  • Page 36: Preparation For Sintering Sinter Metal

    We recommend bedding in the restorations approx. half way into the sinter beads. Positioning the sintering tray in the inLab Profire ● Position the base plate of the sinter metal tray on the door insulation. Carefully place the sintering tray with the restorations and the cover centrally on the base plate and the sintering bell over it.
  • Page 37: Speed Sintering Mode

    Speed sintering mode 5.11 WARNING Risk of burns if used incorrectly! The inLab Profire high-temperature furnace opens at temperatures >1000°C (1832°F). ➢ The internal company safety regulations for working on laboratory furnaces apply. ➢ Always stand when loading the furnace.
  • Page 38: Care And Maintenance

    Dentsply Sirona 6.1 Service programs Operating Instructions inLab Profire Care and maintenance The inLab Profire high-temperature furnace does not require any special care. The casing may be cleaned with a mild detergent. IMPORTANT Damage to the heating unit! ➢ Make sure that the heating chamber does not become dirty. The heating unit could be damaged.
  • Page 39: Faults And Error Messages

    Risk of fatality posed by electric shock. ➢ Work on electrical systems must only be performed by electrical specialists. ➢ Disconnect the power supply of the inLab Profire high- temperature furnace before installation, maintenance, cleaning, and repair work, and ensure that the power will not be inadvertently switched on.
  • Page 40: Decommissioning

    ● For the purpose of reinstalling at another location. ● For the purpose of ultimate disposal. If the inLab Profire high-temperature furnace is to be set up at a different location, decommissioning must be well prepared. All structural components and fasteners must be carefully disassembled, labeled, and, if necessary, packaged for transport.
  • Page 41: Disposal

    Dentsply Sirona 9 Disposal Operating Instructions inLab Profire Disposal In accordance with Directive 2012/19/EU and national disposal regulations regarding old electrical and electronic devices, please be advised that such items must be disposed of in a special way within the European Union (EU).
  • Page 42: D3770

    We reserve the right to make any alterations which may be required due to technical improvements. © Sirona Dental Systems GmbH Sprache: englisch Printed in Germany D3770.201.01.02.02      05.2019 Ä.-Nr.:  127 284 Sirona Dental Systems GmbH 67 15 887 D3770 Fabrikstr. 31 Order No   ...

This manual is also suitable for:

Inlab prosinter

Table of Contents

Save PDF