Direct-current anode

VPB 200E is factory equipped with direct-current anode
and supplied potentiostat. The anode cable (W1) is in-
stalled in the anode from the factory and only needs to
be connected to the potentiostat.
1. Route the anode cable (W1) along the docking pipe,
flow line (XL8).
2. Connect the anode cable (W1) to the potentiostat.
3. Connect the potensiostat to a suitable 230 V wall
socket.
NOTE
The cable between the potentiostat and the
anode must either be extended or shortened.
The figure shows VPB 200 E.
VPB/VPBS
Chapter 5 |
Electrical installation