Next NI2400 User Manual page 72

24-channel ethernet data logger with embedded web server
Table of Contents

Advertisement

9
DETAILED 
SPECIFICATIONS
SOFTWARE & FIRMWARE
• Web server on board (independent OS platform)
• Acquisition Time Interval: selectable from 1 second up to 1 week (depends
on the number of channels acquired)
• FTP client to send data/alarms on an FTP server (SFTP not supported)
• MAIL to send data/alarms to max 5 email address (SMTPS / SSL not sup-
ported)
• SMS to send alarms to max 5 telephone numbers
• Data download (readings, logs) in .csv file (compatible with Microsoft Excel)
• Virtual channels management
• Languages: Italian, English and French
SYSTEM POWER REQUIREMENTS
Voltage (External
10 to 30 Vdc (reverse polarity protected)
Power Supply)
External Recharge-
12 Vdc nominal
able Batteries
Typical Current
Sleep Mode(MAX): 315 µA
Drain (@12 Vdc,
ON: 62 mA - ON with ethernet connected: 87 mA - ON with display ON:
External Power
115 mA
Supply)
ON with display ON and ethernet connected: 142 mA
Analog
115 mA
Initialization
Measurement
123 mA (with 12 mA @ 24 V sensor consumption)
www.ruggedaq.com
9
DETAILED 
SPECIFICATIONS
ENVIROMENTAL CONDITIONS
Operating
Temperature
Storage
Temperature
Relative Humidity
Overvoltage
Category
Pollution Degree
Sound Levels
Maximum Height
of Use
0142
-30 to 70°C (display -20 to 70°C)
-40 to 85°C (display -30 to 80°C)
80 %RH
II
2
< 74 dBA
3000 m (9800 ft)