CONFIGURE THE DATALOGGER
IOT section
Connect to the datalogger through its web server and navigate to the page Configuration →
Logger
In this page you have to enable the IOT feature checking IOT Enable check box and in
the IOT Cik enter the CIK obtained in the previous step in the Exosite portal.
In this way you create the association between this physical device and the virtual
device added in the Exosite portal in the previous step.
Connections Configuration
Navigate to the page Advanced > Connections
www.ruggedaq.com
Figure 95
5
DATALOGGER
NI2400
In this page you should configure all parameters that allow the datalogger to access
the Internet.
These settings depend on your network configuration.
Acquisition configuration
Configure the datalogger for the acquisitions that you need.
Every configured input (analog, digital, mux, virtual) is a data source for your Exosite
portal. The identification name that you give to the input is also the alias that will iden-
tify this input on the Exosite portal.
In the following example two analog sensors have been added to datalogger configuration.
The first is sensor has two inputs (VW + NTC) called AN_1_A and AN_1_B
The second sensor has just one input (Voltage) called AN_2_A
Figure 97