Next NI2400 User Manual page 55

24-channel ethernet data logger with embedded web server
Table of Contents

Advertisement

5
DATALOGGER
NI2400
Figure 99
AN_1_A, AN_1_B and AN_2_B are e xactly the alias for the data source that must be
configured in the Exosite portal in the next step.
ADD DATA SOURCES
On the Exosite portal, go to the device page by clicking on Device menu item. In the
device list you should find the device (NI2400 in this example) added on chapter 1.
By clicking on this device you should reach the configuration page of this device. In
the top right of this page you have the data list where you can see the data source
associated to this device. At the moment the list should be empty; you can add data
source with the button Add Data.
Figure 101
Here you should add all the data source configured on the physical device in the first
paragraph in this chapter
In this example the data source will be added AN_1_A, AN_1_B and AN_2_A.
By clicking on Add Data you get the following page:
www.ruggedaq.com
Figure 100
5
DATALOGGER
NI2400
WARNING: Only use "A-Z,a-z,0-9,_" characters in Alias and channel identification.
In this page it is important that following field must be set in the following way:
Data Source Format : string
Alias : the name of the input configured on omnia in chapter 2, AN_1_A in this example
The field Data Source Name can be used to insert a description of the input; the other
field should be left to default.
After saving the configuration you should repeat the procedure for all the input config-
ured on omnia during chapter 2.
After this steps, come back to Device page and by clicking on device name you should
see the list of all the data source added to this device, in this example AN_1_A,
AN_1_B and AN_2_A:
0108
www.ruggedaq.com
Figure 102