Warning: The installed safety device must
ensure the safety of the door
according to EN13241-1 (EN12453,
EN12445)
If TB stop NC contact is not used it must be
jumpered.
If the FTC input NC is not used it must be
jumpered to 14 terminal
Connections with reflex
com
nc
+
14
3- Technical specifications
Reception frequency
Sensibility (finely tuned signal)
Power supply
Operating temperature range
Maximum power at the motor:
Voltage
Maximum power
Maximum commutable power
at output courtesy lamp
-
12/15 Vdc
if the FTC input are
15
not used put a bridge
between 14 and 15
terminals
868.3 MHz
1 uV
240 V
-20° – +50°C
250 V
400 W
240 V
Connections with photocells
Antenna
The correct installation and connection of the
antenna is fundamental in order to obtain a good
action ray for the installation.
Connect the provided 8.5 cm piece of wire to the
antenna pole connection on the device.
As an alternative (and for better results) use a
tuned antenna connected to the receiver via
coaxial cable RG58 (impedance 50ohm) with a
300 W
maximum length of 15 metres (mod. ANT868)
2
8,2Kohm
resistance
if the FTC input are
14
15
not used put a bridge
between 14 and 15
terminals
TB