8.0- Acoustic signals emitted by the control unit

Beep ...
It is possible to close the door also with a not working CSP or with a negative safety
test (forced closing), by pressing and holding down the closing push button; after 5 s
the control unit closes in dead man mode.
TB Led and FTC Led:
The LED switches off every time that the autotest is done.

9.0- Safety inputs function

-TB: Normally closed input, stop-push-button stops the movement in each condition. (It is not possible
the forced closing)
- Traditional photocell input (inputs 12-13-14-15); if not used jumper the inputs 14-15 (it only works in
closure).
WARNING: all the devices invert the movement for 2 sec.
If the safety is broken it is possible to close the door with a maintained closing command; press the
command for >5sec.; after this time the movement is in dead man mode.
WARNING
The above mentioned product must be installed only by qualified technical personnel in
compliance with the standards of automatic openings. All connections must be rated for a
single-phase power supply of 240V. For the disconnection from the power line, use an all-
pole switch with contact with an opening of at least 3,5mm. Only suitable materials for the
connections must be used to guarantee insulation that complies with current standards on the
subject of electrical safety. The programmer carries out movement controls; all the necessary
safety devices are to be seen separately.
Incorrect wiring will cause incorrect functioning impairing the safety purpose for which the
product has been designed so that people injuries could occur; failure to follow instructions
can cause personal injury and/or property damage.
The correct working of the product must be checked once a year.
Keep the 240V wires from the low voltage safety wires separately. The earth-wires must be fixed
by means of an additional fastening nearby the terminals; this fastening has to be done by qualified
technical personnel during the installation phase.
The appliance has been tested with a power supply wire type H05VV-F; the power supply wires for
outdoor use have not to be lighter than the ordinary wires type H05RN-F. The safety devices have to
be in conformity with EN12978. The installation of the control unit has to be done by fixing the box
vertically with the clamps downwards.
The programmer is in conformity with the RAEE and RoHS directive.
The earth wire must be longer than the other wires because it must be the last to break off if
the cable clamps are slack.
Remember that there are specific standards that must be complied with both as regarding
the safety of the electrical systems and as regarding the remote control of tubular motors for
roller blind.
In the view of a constant development of their products, the manufacturer reserves the right for
changing technical data and features without prior notice.
1 beep: reset
2 beeps: motor is not connected
3 beeps: error on FTC input (FTC is activated)
5 beeps: error on safeties test (safeties test failed)
8 beeps: Limit switch error
ON: TB and FTC input alarm not activated,
the inputs work normally.
OFF: input alarm activated, security alarmed