5. Monitoring, Testing & Maintenance
The CO Alarm self checks vital functions to ensure that it is operating correctly.
1.
Low battery fault – the battery voltage is measured and compared against a
low voltage threshold.
2.
Sensor Fault – the sensor is checked for electrical continuity and open circuit.
life of the Alarm has been exceeded.
Table D: Monitoring & Testing Summary
Red LED
Status Result
(Alarm)
Standby
No visual or audible indication if unit is OK
Unit OK ( Button Test)
Off
Low Battery
Off
Sensor Fault
Off
End of Life (EOL)
Off
*
Note
- For Ei208 models replace the Alarm
.
Monitoring
Amber LED
Green LED
Sounder
(Fault)
(Power)
Off
On
On
1 Flash
Off
1 Beep
2 Flashes
Off
2 Beeps
3 Flashes
Off
3 Beeps
- For Ei207 models (see low battery instructions)
If necessary it is possible
LCD Display
LCD Display
Action
(version 1)
(version 2)
000
See Note
Replace Alarm
Replace Alarm
18