Ei Electronics Ei207 Series Instructions For Use Manual page 10

Battery powered carbon monoxide alarm for use in homes, caravans, motor caravans and boats
Hide thumbs Also See for Ei207 Series:
Table of Contents

Advertisement

Table B-2: CO Alarm Response - (version 2)
Red Light
(Pre Alarm)
CO Gas Level
Off*
0 < ppm < 10 ppm
Off*
10 < ppm < 30 ppm
30 < ppm < 43 ppm
Off*
1 flash
43 < ppm < 80 ppm
every 2 secs
2 flashes
80 < ppm < 150 ppm
every 2 secs
4 flashes
> 150 ppm
every 2 secs
* unless it has alarmed previously (see CO Alarm Memory below)
ppm values shown in table are for example purposes only
9
Display Icon
Display Icon
(before horn sounds)
(after horn sounds)
Blank
Blank
PPM level (flash)
PPM level (flash)
on - 4 seconds,
on - 4 seconds,
off - 12 seconds
off - 12 seconds
PPM level
PPM level
060
060
100
100
150
150
Sounder
(Alarm)
Off
Off
Off
on within 60-90 mins
(typ 72 mins)
on within 10-40 mins
(typ 18 mins)
on within 2 mins
(typ 40 secs)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ei207Ei208 seriesEi207dEi208Ei208wEi208dwrf ... Show all

Table of Contents