Where To Place Co Alarms - Ei Electronics Ei207 Series Instructions For Use Manual

Battery powered carbon monoxide alarm for use in homes, caravans, motor caravans and boats
Hide thumbs Also See for Ei207 Series:
Table of Contents

Advertisement

Table C: CO Alarm Memory Indicators
CO Gas Level
ppm > 43 ppm
ppm > 80 ppm
ppm > 150 ppm
Reset Memory: Hold down the test button until the red light stops and the green
light starts flashing. Cover the horn with a cloth to muffle the alarm during this time.
Please note that the memory will also be reset when the CO Alarm is switched off.

3. Where to place CO Alarms

3.1 Ideally a Carbon Monoxide Alarm should be installed in:
- Every room containing a fuel burning appliance, and
- Remote rooms where occupants spend a considerable amount of time
- Every bedroom
However if the number of Carbon Monoxide Alarms to be fitted is limited, the
- If there is an appliance in a room where people sleep, place a CO Alarm in
this room
- Locate a CO Alarm in a room containing a flueless or open-flued appliance, and
Red Light Response
24 Hours
2 flashes every minute (approx)
4 flashes every minute (approx)
8 flashes every minute (approx)
On Demand (Button Press)
2 flashes
4 flashes
8 flashes
10