Ei Electronics RadioLINK Ei200MRF Instructions Manual

Radiolink module for battery powered carbon monoxide alarms ei207 & ei208 series

Advertisement

RadioLINK Module
for Battery Powered
Carbon Monoxide Alarms
Ei207 & Ei208 Series
Ei200MRF Module
Instructions
Read and retain carefully for as long as the product is being used. It contains vital information on the operation and installation
of your Module. The leaflet should be regarded as part of the product.
If you are just installing this Module, the leaftet must be given to the householder. The leaflet is to be given to any subsequent
user.

Advertisement

Table of Contents
loading

Summary of Contents for Ei Electronics RadioLINK Ei200MRF

  • Page 1 RadioLINK Module for Battery Powered Carbon Monoxide Alarms Ei207 & Ei208 Series Ei200MRF Module Instructions Read and retain carefully for as long as the product is being used. It contains vital information on the operation and installation of your Module. The leaflet should be regarded as part of the product. If you are just installing this Module, the leaftet must be given to the householder.
  • Page 2: Table Of Contents

    Table of Contents page Introduction ................Installation ................Interconnection with RadioLINK Modules ......... RadioLINK Troubleshooting ............Testing ..................Getting your Alarm Serviced ............. Guarantee ................Technical Specification ............. Contact Us ................
  • Page 3: Introduction

    Introduction Congratulations on purchasing an Ei200 Series RF RadioLINK module. This RF module can be easily installed in the RF upgradeable Ei207 or Ei208 Series Carbon Monoxide Alarms to provide you with an RF interconnected warning system – when one Alarm senses carbon monoxide gas and sounds a warning, all the other Alarms will also sound a warning.
  • Page 4 fold over House pull tag Code Button Blue Light Antenna Figure 1 Figure 2 4. Twist the Alarm onto its mounting plate. 5. Similarly press and hold the House Code button on the second Alarm until its blue light comes on and then release. Twist the Alarm onto its mounting plate. Put all the remaining Alarms into House Code mode similarly and attach to the mounting plate in the same manner in less than 15 minutes.
  • Page 5 For example with 3 Alarms in your system, you should see 3 blue light flashes every 5 Blue RF seconds, with 4 Alarms in your system you Light should see 4 blue light flashes and so on, (with the 10th unit, the blue flash is longer, to help with the counting of the flashes).
  • Page 6: Interconnection With Radiolink Modules

    Interconnection with RadioLINK Modules A maximum of 12 Alarms with RF RadioLINK Modules may be interconnected so that if one of the Alarms senses carbon monoxide gas, and sounds a warning, all the other Alarms will also sound a warning. This helps to ensure the alarm will be heard throughout the property.
  • Page 7: Radiolink Troubleshooting

    RadioLINK Troubleshooting It is imperative that all Alarms in your system communicate with each other. The number of walls, ceilings and metal objects in the signal path reduces the strength of the RadioLINK signals between the Alarms. Accordingly, one or more Alarms may have difficulties in communicating to all the other Alarms in the system.
  • Page 8: Testing

    - Repeat this procedure for all other Alarms in the system. Limitations of RadioLINK Radio Frequency Signals Ei Electronics radio communication systems are very reliable and are tested to high standards. However, due to their low transmitting power and limited range (required...
  • Page 9: Getting Your Alarm Serviced

    This guarantee excludes incidental and consequential damage. If this RF RadioLINK Module should become defective within the guarantee period, it must be returned to Ei Electronics, with proof of purchase, carefully packaged, with the problem clearly stated. We shall at our discretion repair or replace the faulty unit.
  • Page 10: Technical Specification

    Technical Specification Operating Freq: 868.499MHz +/- 20 kHz Output power: 10dBm (nom) Range: 250m in free air (min) Protocol: Radiolink Alarm Transmit Interval: 10 sec Initial Alarm duration: 3.5 sec Short Alarm duration: 50 ms Status Message duration: 50 ms Weight: 8 grams...
  • Page 11: Contact Us

    Aico Ltd. Mile End Business Park, Maesbury Rd, Oswestry, Shropshire SY10 8NN, U.K. Tel: 0870 758 4000 www.aico.co.uk Ei Electronics. Shannon, Co Clare, Ireland. Tel: 061 471277 www.eielectronics.com Block E1 The crossed out wheelie bin symbol that is on your product indicates that this product should not be disposed of via the normal household waste stream.